Literature DB >> 18606747

Accuracy of three-dimensional (3D) craniofacial cephalometric landmarks on a low-dose 3D computed tomograph.

R Olszewski1, H Reychler, G Cosnard, J M Denis, S Vynckier, F Zech.   

Abstract

OBJECTIVES: The aim of this paper is to compare the accuracy of cephalometric landmark identification using three-dimensional CT (3D-CT) surface rendering with "high-dose" (200 mAs) and "low-dose" (35 mAs) CT protocols. The absorbed dose levels for radiosensitive organs in the maxillofacial region during the exposure for both 3D-CT protocols were also measured.
METHODS: The study population consisted of 15 human dry skulls examined with spiral 3D-CT. 12 cephalometric anatomical landmarks at 7 sites were identified on the 3D-CT surface renderings by 2 observers independently, twice each, using high-dose and low-dose protocols. In total, 1440 imaging measurements were made. Thermoluminescent dosemeters (TLDs) were placed at ten sites around the thyroid and submandibular glands and the eyes in an Alderson phantom for measuring the absorbed dose levels.
RESULTS: The intraobserver mean distances between 3D landmarks were smaller for all sites with the high-dose protocol (P = 0.37). There was a significant difference among the observers (P = 0.000004). Interobserver mean distances between 3D landmarks were smaller for four of the seven sites with the low-dose protocol. However, the global interobserver mean distances between 3D landmarks for all sites were smaller with the high-dose protocol (P = 0.028). The low-dose protocol reduced the radiation dose to the thyroid by 6.12, to the submandibular salivary glands by 5.91 and to the eye by 5.44, resulting in a global reduction factor of 5.71.
CONCLUSIONS: The accuracy in the landmark's identification was maintained when the milliampere-second values were reduced from 200 mAs to 35 mAs. We recommend use of the low-dose protocol for clinical 3D-CT cephalometric applications.

Entities:  

Mesh:

Year:  2008        PMID: 18606747     DOI: 10.1259/dmfr/33343444

Source DB:  PubMed          Journal:  Dentomaxillofac Radiol        ISSN: 0250-832X            Impact factor:   2.419


  6 in total

1.  Reproducibility of three-dimensional cephalometric landmarks in cone-beam and low-dose computed tomography.

Authors:  R Olszewski; L Frison; M Wisniewski; J M Denis; S Vynckier; G Cosnard; F Zech; H Reychler
Journal:  Clin Oral Investig       Date:  2012-02-17       Impact factor: 3.573

2.  Reproducibility of three-dimensional posterior cranial base angles using low-dose computed tomography.

Authors:  R Olszewski; L Frison; N Schoenarts; R H Khonsari; G A Odri; F Zech; H Reychler
Journal:  Clin Oral Investig       Date:  2016-12-21       Impact factor: 3.573

3.  New 3-dimensional cephalometric analysis for orthognathic surgery.

Authors:  Jaime Gateno; James J Xia; John F Teichgraeber
Journal:  J Oral Maxillofac Surg       Date:  2011-01-22       Impact factor: 1.895

4.  Three-dimensional localization of impacted canines and root resorption assessment using cone beam computed tomography.

Authors:  Eyad Almuhtaseb; Jing Mao; Derek Mahony; Rawan Bader; Zhi-Xing Zhang
Journal:  J Huazhong Univ Sci Technolog Med Sci       Date:  2014-06-18

5.  Comparison of common hard tissue cephalometric measurements between computed tomography 3D reconstruction and conventional 2D cephalometric images.

Authors:  Oded Yitschaky; Meir Redlich; Yossi Abed; Marina Faerman; Nardy Casap; Nurith Hiller
Journal:  Angle Orthod       Date:  2011-01       Impact factor: 2.079

6.  Evaluation of accuracy of 3D reconstruction images using multi-detector CT and cone-beam CT.

Authors:  Mija Kim; Kyung-Hoe Huh; Won-Jin Yi; Min-Suk Heo; Sam-Sun Lee; Soon-Chul Choi
Journal:  Imaging Sci Dent       Date:  2012-03-22
  6 in total