Literature DB >> 18606377

The relation between coronary flow rate, plasma endothelin-1 concentrations, and clinical characteristics in patients with normal coronary arteries.

Huseyin Celebi1, Alp Burak Catakoglu, Hilal Kurtoglu, Murat Sener, Ruken Hanavdelogullari, Cemsid Demiroglu, Vedat Aytekin, Saide Aytekin.   

Abstract

BACKGROUND: Coronary slow flow (CSF) is characterized by delayed opacification of epicardial arteries in the absence of occlusive disease. In the present study, we aimed to investigate the relation between coronary flow rate, plasma endothelin-1 (ET-1) concentrations, and clinical characteristics in patients with normal coronary arteries.
METHODS: The study population included 77 patients with angiographically normal coronary arteries who underwent coronary angiography on suspicion of ischemic heart disease due to typical chest pain or ischemic findings on treadmill exercise test or myocardial scintigraphy. Based on the Thrombolysis In Myocardial Infarction frame count (TFC), patients were grouped into those with normal coronary flow and those with slow coronary flow.
RESULTS: Forty-eight (61.5%) patients were found to have CSF. Plasma ET-1 concentrations were significantly higher with the presence of CSF (P=.03). There were significant differences between plasma ET-1 concentrations, and mean TFC, TFC for left anterior descending coronary artery (LAD), TFC for left circumflex coronary artery (CX), and TFC for right coronary artery separately in patients with and without CSF (P=.033, P<.001, P<.001, P<.001, and P<.001, respectively). Mean TFC, TFC for LAD, and TFC for CX, and ET-1 concentrations were significantly higher in smokers than in nonsmokers (P<.001, P<.001, P=.004, and P=.033, respectively). However, logistic regression analysis suggested that ET-1 concentration was not an independent determinant of CSF.
CONCLUSIONS: Although there is a significant relation between ET-1 concentrations and coronary flow rate, ET-1 concentrations are not sufficient to determine the presence of CSF. Smoking is strongly associated with CSF, TFC, and increased ET-1 concentrations.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18606377     DOI: 10.1016/j.carrev.2007.11.002

Source DB:  PubMed          Journal:  Cardiovasc Revasc Med        ISSN: 1878-0938


  11 in total

Review 1.  Working under pressure: coronary arteries and the endothelin system.

Authors:  Albert Nguyen; Nathalie Thorin-Trescases; Eric Thorin
Journal:  Am J Physiol Regul Integr Comp Physiol       Date:  2010-03-17       Impact factor: 3.619

2.  Ventricular Dysfunction in Patients with Coronary Slow-Flow Phenomenon: A Single-center Case-control Study.

Authors:  Mir Hossein Seyyed-Mohammadzad; Sanam Rashtchizadeh; Kamal Khademvatani; Roghaiyeh Afsargharehbagh; Aliakbar Nasiri; Nariman Sepehrvand
Journal:  Heart Views       Date:  2020-06-29

Review 3.  Endothelium-derived endothelin-1.

Authors:  Eric Thorin; David J Webb
Journal:  Pflugers Arch       Date:  2009-12-05       Impact factor: 3.657

4.  Assessment of left and right ventricular diastolic and systolic functions using two-dimensional speckle-tracking echocardiography in patients with coronary slow-flow phenomenon.

Authors:  Yonghuai Wang; Chunyan Ma; Yan Zhang; Zhengyu Guan; Shuang Liu; Yuling Li; Jun Yang
Journal:  PLoS One       Date:  2015-02-23       Impact factor: 3.240

5.  Nicorandil improves myocardial function by regulating plasma nitric oxide and endothelin-1 in coronary slow flow.

Authors:  Zuoyuan Chen; Xiuhua Chen; Shan Li; Xuezhen Huo; Xiuxiu Fu; Xiaonan Dong
Journal:  Coron Artery Dis       Date:  2015-03       Impact factor: 1.439

6.  The relationship between coronary slow flow phenomenon and urotensin-II: A prospective and controlled study.

Authors:  Halit Zengin; Ali Rıza Erbay; Ali Okuyucu; Hasan Alaçam; Serkan Yüksel; Murat Meriç; Korhan Soylu; Ömer Gedikli; Naci Murat; Okan Gülel; Sabri Demircan; Filiz Akın; Özcan Yılmaz; Mahmut Şahin
Journal:  Anatol J Cardiol       Date:  2014-04-28       Impact factor: 1.596

7.  Statistical analysis plan for "A randomised, controlled study to evaluate the effects of switching from cigarette smoking to using a tobacco heating product on health effect indicators in healthy subjects".

Authors:  Oscar M Camacho; Andrew Hedge; Frazer Lowe; Nik Newland; Nathan Gale; Mike McEwan; Christopher Proctor
Journal:  Contemp Clin Trials Commun       Date:  2020-01-28

8.  Echocardiographic and laboratory findings in coronary slow flow phenomenon: cross-sectional study and review.

Authors:  Mir Hosein Seyyed Mohammadzad; Kamal Khademvatani; Salar Gardeshkhah; Amin Sedokani
Journal:  BMC Cardiovasc Disord       Date:  2021-05-05       Impact factor: 2.298

9.  Plasma Choline as a Diagnostic Biomarker in Slow Coronary Flow.

Authors:  Yuan-Ting Zhu; Ling-Ping Zhu; Zhen-Yu Wang; Xue-Ting Qiu; Wan-Zhou Wu; Wei-Wang Liu; Yu-Yu Feng; Wen-Kai Xiao; Xin Luo; Zhen-Yu Li; Chuan-Chang Li
Journal:  Cardiol Res Pract       Date:  2020-01-25       Impact factor: 1.866

10.  Evaluation of the Correlation between Serum Concentrations of Asymmetric Dimethylarginine and Corrected TIMI Frame Count in Patients with Slow Coronary Flow.

Authors:  Mahshid Naserifar; Mahshid Ataei; Nadia Behzadian; Amir Hooshang Mohammadpour; Mostafa Dastani; Amirhossein Sahebkar; Hesamoddin Hosseinjani
Journal:  Int J Vasc Med       Date:  2020-09-19
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.