Literature DB >> 18605545

Nitrification in premise plumbing: role of phosphate, pH and pipe corrosion.

Yan Zhang1, Allian Griffin, Marc Edwards.   

Abstract

Nitrification in PVC premise plumbing is a weak function of pH over the range 6.5--8.5 and is insensitive to phosphate concentrations 5--1000 ppb. Lead pipe enhanced nitrification relative to PVC, consistent with expectations that nitrifiers could benefit from ammonia recycled from nitrate via lead corrosion. Relatively new copper pipe (< 1.5-years-old) did not allow nitrifiers to establish, but nitrifiers gradually colonized over a period of months in brass pipes when copper concentrations were reduced by pH adjustment or orthophosphate. Nitrifiers were inhibited by trace copper, but not by lead levels up to 8000 ppb. In some systems using chloramines, brass in plastic plumbing systems might be more susceptible to lead/copper leaching, and accelerated dezincification, due to lower pH values resulting from nitrification.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18605545     DOI: 10.1021/es702483d

Source DB:  PubMed          Journal:  Environ Sci Technol        ISSN: 0013-936X            Impact factor:   9.028


  6 in total

1.  Microbial survey of a full-scale, biologically active filter for treatment of drinking water.

Authors:  Colin P White; Ronald W Debry; Darren A Lytle
Journal:  Appl Environ Microbiol       Date:  2012-06-29       Impact factor: 4.792

2.  Microbial community profile of a lead service line removed from a drinking water distribution system.

Authors:  Colin White; Matthew Tancos; Darren A Lytle
Journal:  Appl Environ Microbiol       Date:  2011-06-07       Impact factor: 4.792

3.  Spatial-temporal survey and occupancy-abundance modeling to predict bacterial community dynamics in the drinking water microbiome.

Authors:  Ameet J Pinto; Joanna Schroeder; Mary Lunn; William Sloan; Lutgarde Raskin
Journal:  MBio       Date:  2014-05-27       Impact factor: 7.867

4.  Effectiveness of Devices to Monitor Biofouling and Metals Deposition on Plumbing Materials Exposed to a Full-Scale Drinking Water Distribution System.

Authors:  Maneesha P Ginige; Scott Garbin; Jason Wylie; K C Bal Krishna
Journal:  PLoS One       Date:  2017-01-06       Impact factor: 3.240

5.  Factors Associated With High Blood Lead Levels in a Sample of 100 Children in Tehran.

Authors:  Nasim Zamani; Narges Gholami; Hossein Hassanian-Moghaddam; Fariba Farnaghi; Latif Gachkar
Journal:  Clin Med Insights Pediatr       Date:  2019-03-25

6.  Disinfection exhibits systematic impacts on the drinking water microbiome.

Authors:  Zihan Dai; Maria C Sevillano-Rivera; Szymon T Calus; Q Melina Bautista-de Los Santos; A Murat Eren; Paul W J J van der Wielen; Umer Z Ijaz; Ameet J Pinto
Journal:  Microbiome       Date:  2020-03-20       Impact factor: 14.650

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.