Literature DB >> 18602857

Spherical aberration in contact lens wear.

A Lindskoog Pettersson1, C Jarkö, A Alvin, P Unsbo, R Brautaset.   

Abstract

INTRODUCTION: The aim of the present studies was to investigate the effect on spherical aberration of different non custom-made contact lenses, both with and without aberration control.
METHODS: A wavefront analyser (Zywave, Bausch & Lomb) was used to measure the aberrations in each subject's right eye uncorrected and with the different contact lenses. The first study evaluated residual spherical aberration with a standard lens (Focus Dailies Disposable, Ciba Vision) and with an aberration controlled contact lens (ACCL) (Definition AC, Optical Connection Inc.). The second study evaluated the residual spherical aberrations with a monthly disposable silicone hydrogel lens with aberration reduction (PureVision, Bausch & Lomb).
RESULTS: Uncorrected spherical aberration was positive for all pupil sizes in both studies. In the first study, residual spherical aberration was close to zero with the standard lens for all pupil sizes whereas the ACCL over-corrected spherical aberration. The results of the second study showed that the monthly disposable lens also over-corrected the aberration making it negative. The changes in aberration were statistically significant (p<0.05) with all lenses.
CONCLUSION: Since the amount of aberration varies individually we suggest that aberrations should be measured with lenses on the eye if the aim is to change spherical aberration in a certain direction.

Entities:  

Mesh:

Year:  2008        PMID: 18602857     DOI: 10.1016/j.clae.2008.05.005

Source DB:  PubMed          Journal:  Cont Lens Anterior Eye        ISSN: 1367-0484            Impact factor:   3.077


  3 in total

1.  Spherical aberration and higher order aberrations with Balafilcon A (PureVision) and Comfilcon A (Biofinity).

Authors:  Colm McAlinden; Jonathan E Moore; Victoria E McGilligan; Tara C B Moore
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2010-08-06       Impact factor: 3.117

2.  Impact of pupil transmission apodization on presbyopic through-focus visual performance with spherical aberration.

Authors:  Len Zheleznyak; HaeWon Jung; Geunyoung Yoon
Journal:  Invest Ophthalmol Vis Sci       Date:  2014-01-03       Impact factor: 4.799

3.  Comparing the optical properties of soft contact lenses on and off the eye.

Authors:  Pete S Kollbaum; Arthur Bradley; Larry N Thibos
Journal:  Optom Vis Sci       Date:  2013-09       Impact factor: 1.973

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.