| Literature DB >> 18602305 |
Alailson D Santos1, Eudes B Araújo, Keizo Yukimitu, José C Barbosa, João C S Moraes.
Abstract
The purpose of this study was to evaluate the setting time and the thermal expansion coefficient of 2 endodontic cements, MTA-Angelus and a novel cement called CER. The setting time was determined in accordance to ANSI/ADA specifications no. 57. Three samples of 10 mm diameter and 2 mm thickness were prepared for each cement. The thermal expansion measurements were performed by strain gauge technique. Four samples of each cement were prepared using silicone rings of 5 mm diameter and 2 mm thickness. The data were analyzed statistically using the Student t test. The setting time obtained for the MTA-Angelus and CER cements was 15 (SD 1) min and 7 (SD 1) min, respectively. The linear coefficient of thermal expansion was 8.86 (SD 0.28) microstrain/ degrees C for MTA-Angelus and 11.76 (SD 1.20) microstrain/ degrees C for CER. The statistical analysis showed significant difference (P < .05) in the setting time and linear coefficient of thermal expansion between the 2 cements. The CER cement has a coefficient of expansion similar to dentin, which could contribute to a decrease of microleakage degree.Entities:
Mesh:
Substances:
Year: 2008 PMID: 18602305 DOI: 10.1016/j.tripleo.2008.04.021
Source DB: PubMed Journal: Oral Surg Oral Med Oral Pathol Oral Radiol Endod ISSN: 1079-2104