Literature DB >> 18599421

High-speed optical observations and simulation results of SonoVue microbubbles at low-pressure insonation.

Kevin Chetty1, Eleanor Stride, Charles A Sennoga, Joseph V Hajnal, Robert J Eckersley.   

Abstract

Abstract-Modified Rayleigh-Plesset models are commonly used to characterize the acoustic response of microbubbles under ultrasound exposure. In most instances these models have been parameterized through acoustic measurements taken from bulk suspensions of microbubbles. The aim of this study was to parameterize the Hoff model for the commercial contrast agent SonoVue using optically observed oscillations from individual microbubbles recorded with a high-speed camera. The shell elasticity model term was tuned to fit simulation data to the measured oscillations while the shell viscosity parameter was held constant at 1 Pa??s. The results demonstrate a limited ability of the model to predict the microbubble behavior. The shell elasticity parameter was found to vary proportionally between 10 and 80 MPa with the initial microbubble diameter, implying the viscoelastic shell terms are not a constant property of the shell material. Further analysis using a moving window optimization to probe the microbubble responses suggests that the elasticity of the shell can increase by up to 50% over the course of insonation, particularly for microbubbles oscillating nearer to their resonant frequency. Microbubble oscillations were modeled more successfully by incorporating a varying elasticity term into the model.

Mesh:

Substances:

Year:  2008        PMID: 18599421     DOI: 10.1109/TUFFC.2008.796

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  5 in total

1.  Impulse response method for characterization of echogenic liposomes.

Authors:  Jason L Raymond; Ying Luan; Tom van Rooij; Klazina Kooiman; Shao-Ling Huang; David D McPherson; Michel Versluis; Nico de Jong; Christy K Holland
Journal:  J Acoust Soc Am       Date:  2015-04       Impact factor: 1.840

2.  Loss of gas from echogenic liposomes exposed to pulsed ultrasound.

Authors:  Jason L Raymond; Ying Luan; Tao Peng; Shao-Ling Huang; David D McPherson; Michel Versluis; Nico de Jong; Christy K Holland
Journal:  Phys Med Biol       Date:  2016-11-03       Impact factor: 3.609

3.  Encapsulated microbubbles and echogenic liposomes for contrast ultrasound imaging and targeted drug delivery.

Authors:  Shirshendu Paul; Rahul Nahire; Sanku Mallik; Kausik Sarkar
Journal:  Comput Mech       Date:  2014-03       Impact factor: 4.014

Review 4.  Sonobactericide: An Emerging Treatment Strategy for Bacterial Infections.

Authors:  Kirby R Lattwein; Himanshu Shekhar; Joop J P Kouijzer; Willem J B van Wamel; Christy K Holland; Klazina Kooiman
Journal:  Ultrasound Med Biol       Date:  2019-11-05       Impact factor: 3.694

5.  High-Frequency Array-Based Nanobubble Nonlinear Imaging in a Phantom and In Vivo.

Authors:  Carly Pellow; Emmanuel Cherin; Eric C Abenojar; Agata A Exner; Gang Zheng; Christine E M Demore; David E Goertz
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2021-05-25       Impact factor: 3.267

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.