Literature DB >> 18599239

Advances of dual source, dual-energy imaging in postmortem CT.

Anders Persson1, Christian Jackowski, Elias Engström, Helene Zachrisson.   

Abstract

This paper focuses on the use of multi-detector row dual-energy computed tomography (DECT) in the evaluation of postmortal examinations. The use of dual energy moves postmortem CT to an entirely new dimension of diagnostic sensitivity where contrast in the image is not merely limited to X-ray attenuation differences, but may include elements of functional and tissue characterization. This additional information may be used to improve the benefit postmortem imaging can provide to supplement and simplify the conventional autopsy.

Mesh:

Year:  2008        PMID: 18599239     DOI: 10.1016/j.ejrad.2008.05.008

Source DB:  PubMed          Journal:  Eur J Radiol        ISSN: 0720-048X            Impact factor:   3.528


  9 in total

1.  Virtual CT autopsy in clinical pathology: feasibility in clinical autopsies.

Authors:  Saskia E Westphal; Jonas Apitzsch; Tobias Penzkofer; Andreas H Mahnken; Ruth Knüchel
Journal:  Virchows Arch       Date:  2012-06-23       Impact factor: 4.064

2.  Postmortem CT versus forensic autopsy: frequent discrepancies of tracheobronchial content findings.

Authors:  Wolf-Dieter Zech; Christian Jackowski; Nicole Schwendener; Eva Brencicova; Frederick Schuster; Paolo Lombardo
Journal:  Int J Legal Med       Date:  2015-09-23       Impact factor: 2.686

3.  X-ray absorption-based imaging and its limitations in the differentiation of ancient mummified tissue.

Authors:  Johann Wanek; Gábor Székely; Frank Rühli
Journal:  Skeletal Radiol       Date:  2011-01-12       Impact factor: 2.199

4.  Material differentiation in forensic radiology with single-source dual-energy computed tomography.

Authors:  Thomas D Ruder; Yannick Thali; Stephan A Bolliger; Sandra Somaini-Mathier; Michael J Thali; Gary M Hatch; Sebastian T Schindera
Journal:  Forensic Sci Med Pathol       Date:  2012-12-21       Impact factor: 2.007

Review 5.  Peering through the glare: using dual-energy CT to overcome the problem of metal artefacts in bone radiology.

Authors:  Tyler M Coupal; Paul I Mallinson; Patrick McLaughlin; Savvas Nicolaou; Peter L Munk; Hugue Ouellette
Journal:  Skeletal Radiol       Date:  2014-01-17       Impact factor: 2.199

6.  Case-control study to estimate the performance of dual-energy computed tomography for anterior cruciate ligament tears in patients with history of knee trauma.

Authors:  Katrina N Glazebrook; Lee J Brewerton; Shuai Leng; Rickey E Carter; Peter C Rhee; Naveen S Murthy; B Mathew Howe; Michael D Ringler; Diane L Dahm; Michael J Stuart; Cynthia H McCollough; J G Fletcher
Journal:  Skeletal Radiol       Date:  2013-12-14       Impact factor: 2.199

7.  Adult post-mortem imaging in traumatic and cardiorespiratory death and its relation to clinical radiological imaging.

Authors:  B Morgan; D Adlam; C Robinson; M Pakkal; G N Rutty
Journal:  Br J Radiol       Date:  2014-04       Impact factor: 3.039

8.  Radiological analysis of a naturally mummified body.

Authors:  Akihito Usui; Yusuke Kawasumi; Yoshiyuki Hosokai; Yoshie Hayashizaki; Haruo Saito; Masato Funayama
Journal:  Jpn J Radiol       Date:  2012-03-13       Impact factor: 2.374

9.  CT-scan vs. 3D surface scanning of a skull: first considerations regarding reproducibility issues.

Authors:  Stella Fahrni; Lorenzo Campana; Alejandro Dominguez; Tanya Uldin; Fabrice Dedouit; Olivier Delémont; Silke Grabherr
Journal:  Forensic Sci Res       Date:  2017-06-13
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.