Literature DB >> 18597598

Clinical outcome of immediately loaded dental implants bioactivated with plasma rich in growth factors: a 5-year retrospective study.

Eduardo Anitua1, Gorka Orive, José Javier Aguirre, Isabel Andía.   

Abstract

BACKGROUND: The aims of this study were to describe a procedure for the immediate loading of dental implants, evaluate the long-term survival rates of 1,139 immediately loaded dental implants, and analyze the influence of different factors on implant survival.
METHODS: A retrospective cohort study design was used. A total of 241 patients received 1,139 immediately loaded implants between 2001 and 2005 in Vitoria, Spain. All implants were placed by one experienced surgeon, and rehabilitations were done by four prosthodontists. Each implant failure was analyzed carefully. The potential influence of demographic, clinical, and surgery-dependent factors and prosthetic variables on implant survival was studied. Implant survival was analyzed using a life-table analysis.
RESULTS: The overall survival rates were 99.3%, 96.8%, and 96.9% for the implant-, surgery-, and patient-based analyses, respectively. The mean follow-up period was 28 +/- 15 months. Five of 1,139 implants were lost during the observation period. No variable studied was statistically associated with implant failure.
CONCLUSION: Based on these results, the procedure described for the immediate loading of implants can be considered safe and predictable if used under strict clinical protocols.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18597598     DOI: 10.1902/jop.2008.070580

Source DB:  PubMed          Journal:  J Periodontol        ISSN: 0022-3492            Impact factor:   6.993


  6 in total

1.  Evaluation of immediately loaded dental implants bioactivated with platelet-rich plasma placed in the mandibular posterior region: A clinico-radiographic study.

Authors:  Ullas Anand; D S Mehta
Journal:  J Indian Soc Periodontol       Date:  2012-01

2.  Effect of two different preparations of platelet-rich plasma on synoviocytes.

Authors:  Elisa Assirelli; Giuseppe Filardo; Erminia Mariani; Elizaveta Kon; Alice Roffi; Franca Vaccaro; Maurilio Marcacci; Andrea Facchini; Lia Pulsatelli
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-06-19       Impact factor: 4.342

3.  Impact of Platelet-Rich Plasma on Bone Height Changes around Platform Switched Implants Supporting Mandibular Overdentures in Controlled Diabetic Patients.

Authors:  Eman Mostafa Ahmed Ibraheem; Amany Mohy Eldeen
Journal:  Open Access Maced J Med Sci       Date:  2015-12-10

4.  Radiographic evaluation of bone regeneration after the application of plasma rich in growth factors in a lower third molar socket: a case report.

Authors:  Ioannis Nazaroglou; Christos Stavrianos; Panagiotis Kafas; Euthimios Matoulas; Tahwinder Upile; Irodis Barlas; Waseem Jerjes
Journal:  Cases J       Date:  2009-12-03

5.  Comparative evaluation of two types of immediately loaded implants using biomechanical and histomorphometric tests: an animal case study.

Authors:  Mansour Rismanchian; Bijan Movahedian; Navid Khalighinejad; Hamid Badrian; Sayed Mohammad Razavi; Afsaneh Nekouie
Journal:  ISRN Dent       Date:  2012-07-18

Review 6.  The use of concentrated growth factor in dental implantology: A systematic review.

Authors:  Bhavna Vasudev Lokwani; Deeksha Gupta; Reema Sarvesh Agrawal; Sonal Mehta; Narendra J Nirmal
Journal:  J Indian Prosthodont Soc       Date:  2020-01-27
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.