Literature DB >> 18595809

Method for determining kinematic parameters of the in vivo thumb carpometacarpal joint.

Lillian Y Chang1, Nancy S Pollard.   

Abstract

The mobility of the thumb carpometacarpal (CMC) joint is critical for functional grasping and manipulation tasks. We present an optimization technique for determining from surface marker measurements a subject-specific kinematic model of the in vivo CMC joint that is suitable for measuring mobility. Our anatomy-based cost metric scores a candidate joint model by the plausibility of the corresponding joint angle values and kinematic parameters rather than only the marker trajectory reconstruction error. The proposed method repeatably determines CMC joint models with anatomically-plausible directions for the two dominant rotational axes and a lesser range of motion (RoM) for the third rotational axis. We formulate a low-dimensional parameterization of the optimization domain by first solving for joint axis orientation variables that then constrain the search for the joint axis location variables. Individual CMC joint models were determined for 24 subjects. The directions of the flexion--extension (FE) axis and adduction--abduction (AA) axis deviated on average by 9 degrees and 22 degrees , respectively, from the mean axis direction. The average RoM for FE, AA, and pronation--supination (PS) joint angles were 76 degrees , 43 degrees , and 23 degrees for active CMC movement. The mean separation distance between the FE and AA axes was 4.6 mm, and the mean skew angle was 87 degrees from the positive flexion axis to the positive abduction axis.

Entities:  

Mesh:

Year:  2008        PMID: 18595809     DOI: 10.1109/TBME.2008.919854

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  9 in total

1.  Subject-Specific Axes of Rotation Based on Talar Morphology Do Not Improve Predictions of Tibiotalar and Subtalar Joint Kinematics.

Authors:  Jennifer A Nichols; Koren E Roach; Niccolo M Fiorentino; Andrew E Anderson
Journal:  Ann Biomed Eng       Date:  2017-06-21       Impact factor: 3.934

2.  A stochastic algorithm for automatic hand pose and motion estimation.

Authors:  Francesca Cordella; Francesco Di Corato; Bruno Siciliano; Loredana Zollo
Journal:  Med Biol Eng Comput       Date:  2017-06-08       Impact factor: 2.602

3.  A method for defining carpometacarpal joint kinematics from three-dimensional rotations of the metacarpal bones captured in vivo using computed tomography.

Authors:  James H Buffi; Joseph J Crisco; Wendy M Murray
Journal:  J Biomech       Date:  2013-07-01       Impact factor: 2.712

4.  Evaluation of hand motion capture protocol using static computed tomography images: application to an instrumented glove.

Authors:  James H Buffi; Joaquín Luis Sancho Bru; Joseph J Crisco; Wendy M Murray
Journal:  J Biomech Eng       Date:  2014-12       Impact factor: 2.097

5.  In Vivo kinematics of the trapeziometacarpal joint during thumb extension-flexion and abduction-adduction.

Authors:  Joseph J Crisco; Eni Halilaj; Douglas C Moore; Tarpit Patel; Arnold-Peter C Weiss; Amy L Ladd
Journal:  J Hand Surg Am       Date:  2014-12-24       Impact factor: 2.230

6.  The Envelope of Physiological Motion of the First Carpometacarpal Joint.

Authors:  Joseph J Crisco; Tarpit Patel; Eni Halilaj; Douglas C Moore
Journal:  J Biomech Eng       Date:  2015-10       Impact factor: 2.097

7.  In vivo kinematics of the thumb carpometacarpal joint during three isometric functional tasks.

Authors:  Eni Halilaj; Michael J Rainbow; Christopher Got; Joel B Schwartz; Douglas C Moore; Arnold-Peter C Weiss; Amy L Ladd; Joseph J Crisco
Journal:  Clin Orthop Relat Res       Date:  2014-04       Impact factor: 4.176

8.  Improving Kinematic Accuracy of Soft Wearable Data Gloves by Optimizing Sensor Locations.

Authors:  Dong Hyun Kim; Sang Wook Lee; Hyung-Soon Park
Journal:  Sensors (Basel)       Date:  2016-05-26       Impact factor: 3.576

9.  A Three-dimensional Finger Motion Measurement System of a Thumb and an Index Finger Without a Calibration Process.

Authors:  Yeongyu Park; Joonbum Bae
Journal:  Sensors (Basel)       Date:  2020-01-30       Impact factor: 3.576

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.