Literature DB >> 18594458

Atlantoaxial transarticular screw fixation with posterior wiring using polyethylene cable: facet fusion despite posterior graft resorption in rheumatoid patients.

Hiromu Ito1, Masashi Neo, Shunsuke Fujibayashi, Masahiko Miyata, Hiroyuki Yoshitomi, Takashi Nakamura.   

Abstract

STUDY
DESIGN: A comparative retrospective study on the posterior graft union and the facet fusion in atlantoaxial transarticular screw fixation.
OBJECTIVE: To evaluate the posterior graft union and the facet fusion in atlantoaxial transarticular screw fixation when a polyethylene (PE) cable was used in rheumatoid and nonrheumatoid patients. SUMMARY OF BACKGROUND DATA: In atlantoaxial transarticular screw fixation, metal wires or cables for posterior bone graft fixation can cause intraoperative or delayed spinal cord compression. PE cables do not have the risk, but there has been no comparative report. Also, a precise evaluation on the posterior graft union and the facet fusion has not been reported.
METHODS: Thirty-eight patients who submitted to atlantoaxial transarticular screw fixation and posterior bone graft without any concomitant operation were followed up for more than 2 years. The posterior graft union and the facet fusion were evaluated by functional radiographs and computed tomography scans.
RESULTS: Seven patients showed the posterior graft nonunion. All of them were rheumatoid patients and received PE cable wiring for posterior internal fixation. However, 5 of the 7 cases presented stable C1-C2 with the facet fusion demonstrated by functional radiographs and computed tomography scans, achieving an overall fusion rate of 95%.
CONCLUSION: In atlantoaxial transarticular screw fixation, the use of PE cable and rheumatoid background are 2 of the unfavorable factors for the posterior graft union. However, atlantoaxial transarticular screws can bring the facet fusion despite the posterior graft failure in such cases.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18594458     DOI: 10.1097/BRS.0b013e31817b5c07

Source DB:  PubMed          Journal:  Spine (Phila Pa 1976)        ISSN: 0362-2436            Impact factor:   3.468


  6 in total

1.  Mechanical implant failure in posterior cervical spine fusion.

Authors:  Takeshi Okamoto; Masashi Neo; Shunsuke Fujibayashi; Hiromu Ito; Mitsuru Takemoto; Takashi Nakamura
Journal:  Eur Spine J       Date:  2011-10-16       Impact factor: 3.134

2.  Atlanto-axial joint of atlanto-axial subluxation patients due to rheumatoid arthritis before and after surgery: morphological evaluation using CT reconstruction.

Authors:  Yasunori Sorimachi; Haku Iizuka; Tsuyoshi Ara; Masahiro Nishinome; Yoichi Iizuka; Takashi Nakajima; Kenji Takagishi
Journal:  Eur Spine J       Date:  2010-11-01       Impact factor: 3.134

3.  Potential intraoperative factors of screw-related complications following posterior transarticular C1-C2 fixation: a systematic review and meta-analysis.

Authors:  Ivan Lvov; Andrey Grin; Aleksandr Talypov; Anton Kordonskiy; Vladimir Smirnov; Iliya Grigoriev; Ulugbek Khushnazarov; Vladimir Krylov
Journal:  Eur Spine J       Date:  2018-11-22       Impact factor: 3.134

4.  Atlantoaxial transarticular screw fixation and posterior fusion using polyester cable: a 10-year experience.

Authors:  Werasak Sutipornpalangkul; Surin Thanapipatsiri
Journal:  Eur Spine J       Date:  2013-04-23       Impact factor: 3.134

5.  Subaxial subluxation after atlantoaxial transarticular screw fixation in rheumatoid patients.

Authors:  Hiromu Ito; Masashi Neo; Takeshi Sakamoto; Shunsuke Fujibayashi; Hiroyuki Yoshitomi; Takashi Nakamura
Journal:  Eur Spine J       Date:  2009-04-01       Impact factor: 3.134

6.  Minimally Invasive Microscope-Assisted Stand-Alone Transarticular Screw Fixation without Gallie Supplementation in the Management of Mobile Atlantoaxial Instability.

Authors:  Tarun Dusad; Vishal Kundnani; Shumayou Dutta; Ankit Patel; Gaurav Mehta; Mahendra Singh
Journal:  Asian Spine J       Date:  2018-07-27
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.