Literature DB >> 18594052

Efficacy of a premedication algorithm for nonemergent intubation in a neonatal intensive care unit.

J W VanLooy1, Robert E Schumacher, Varsha Bhatt-Mehta.   

Abstract

BACKGROUND: Preventing significant oxygen desaturation and hypotension through adequate analgesia and sedation during nonemergent intubation in neonates is desirable. However, in many neonatal intensive care units, elective intubations occur without adequate premedication. There is significant variation in the choice of premedication agent(s) and doses, and an ideal regimen for use during nonemergent intubation has not been developed.
OBJECTIVE: To evaluate the efficacy of an algorithm developed for analgesia and sedation during nonemergent intubation in neonates.
METHODS: Prospectively collected continuous quality improvement data on a premedication algorithm for nonemergent intubation were analyzed following institutional review board approval. Midazolam 0.1 mg/kg and fentanyl 2 microg/kg (if the patient was not already receiving morphine for sedation) were administered prior to nonemergent intubation. Heart rate, oxygen saturation, respiration rate, mean arterial pressure, and pain scores were recorded at baseline prior to medication administration, during the procedure, and for 2 hours after the procedure. Data during laryngoscopy and until the time of tube taping were obtained from the bedside cardiorespiratory monitor. Additional fentanyl was allowed for more than 3 intubation attempts and rocuronium 0.6 mg/kg was allowed for more than 5 attempts. The physiological changes that occurred over time were compared with baseline. The number of attempts made, time to intubation, and medications used are presented.
RESULTS: Ninety evaluable patients were included. Mean +/- SD birth weight and postnatal age at treatment were 2040 +/- 961 g and 14 +/- 17 days, respectively. Heart rate decreased and oxygen saturation increased significantly (160 vs 154 beats/min, p = 0.01; 96.4% vs 93.8%, p = 0.002, respectively) from baseline to completion of the procedure; however, mean arterial pressure showed no significant difference (44.9 vs 44.7 mm Hg; p = 0.85; n = 68). The number of attempts at intubation were recorded for 66 patients; of those, 52 required 3 or fewer attempts for successful intubation (median, 2). The time to successful intubation was 7.2 +/- 5.6 minutes (recorded in 45 pts.). Average fentanyl and midazolam doses were 1.92 +/- 0.53 microg/kg and 0.096 +/- 0.026 mg/kg, respectively. No patient received rocuronium.
CONCLUSIONS: A systematic approach to premedication during nonemergent intubation successfully prevented acute physiological changes.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18594052     DOI: 10.1345/aph.1K665

Source DB:  PubMed          Journal:  Ann Pharmacother        ISSN: 1060-0280            Impact factor:   3.154


  11 in total

1.  Endotracheal intubation in a neonatal population remains associated with a high risk of adverse events.

Authors:  Vidheya Venkatesh; Vennila Ponnusamy; Juliet Anandaraj; Rajiv Chaudhary; Manish Malviya; Paul Clarke; Anusha Arasu; Anna Curley
Journal:  Eur J Pediatr       Date:  2010-09-15       Impact factor: 3.183

2.  Effect of premedication regimen on infant pain and stress response to endotracheal intubation.

Authors:  C D Caldwell; K L Watterberg
Journal:  J Perinatol       Date:  2015-01-08       Impact factor: 2.521

Review 3.  Anesthesia and analgesia in the NICU.

Authors:  R Whit Hall
Journal:  Clin Perinatol       Date:  2012-03       Impact factor: 3.430

Review 4.  Pain management in newborns.

Authors:  Richard W Hall; Kanwaljeet J S Anand
Journal:  Clin Perinatol       Date:  2014-10-07       Impact factor: 3.430

Review 5.  Premedication for neonatal intubation: which medications are recommended and why.

Authors:  Kimberly A Allen
Journal:  Adv Neonatal Care       Date:  2012-04       Impact factor: 1.968

6.  A novel maturation function for clearance of the cytochrome P450 3A substrate midazolam from preterm neonates to adults.

Authors:  Ibrahim Ince; Saskia N de Wildt; Chenguang Wang; Chengueng Wang; Mariska Y M Peeters; Jacobus Burggraaf; Evelyne Jacqz-Aigrain; John N van den Anker; Dick Tibboel; Meindert Danhof; Catherijne A J Knibbe
Journal:  Clin Pharmacokinet       Date:  2013-07       Impact factor: 6.447

7.  Comparison of the effect of fentanyl, sufentanil, alfentanil and remifentanil on cardiovascular response to tracheal intubation in children.

Authors:  Seyed-Mohamad Mireskandari; Navid Abulahrar; Mohamad-Esmaeil Darabi; Iman Rahimi; Fatemeh Haji-Mohamadi; Ali Movafegh
Journal:  Iran J Pediatr       Date:  2011-06       Impact factor: 0.364

8.  Application of Lidocaine Spray for Tracheal Intubation in Neonates - A Clinical Trial Study.

Authors:  Mirhadi Mussavi; Khairollah Asadollahi; Ghobad Abangah; Sirus Saradar; Naser Abbasi; Fereidon Zanjani; Mahsa Aminizade
Journal:  Iran J Pediatr       Date:  2015-02-21       Impact factor: 0.364

9.  Premedication for neonatal intubation: Current practice in Saudi Arabia.

Authors:  Rafat Mosalli; Lana Shaiba; Khalid Alfaleh; Bosco Paes
Journal:  Saudi J Anaesth       Date:  2012 Oct-Dec

10.  A comparison of surfactant administration through i-gel and ET-tube in the treatment of respiratory distress syndrome in newborns weighing more than 2000 grams.

Authors:  Alireza Sadeghnia; Mozhgan Tanhaei; Majid Mohammadizadeh; Mohammad Nemati
Journal:  Adv Biomed Res       Date:  2014-07-31
View more