Literature DB >> 18590406

Rheumatoid arthritis as a risk factor for a narrow C-2 pedicle: 3D analysis of the C-2 pedicle screw trajectory.

Masahiko Miyata1, Masashi Neo, Hiromu Ito, Makoto Yoshida, Shunsuke Fujibayashi, Takashi Nakamura.   

Abstract

OBJECT: Vertebral artery (VA) injury is a potentially serious complication of C-2 pedicle screw (PS) fixation. Although this surgery is frequently performed in patients with rheumatoid arthritis (RA), few studies have compared the risk of VA injury in patients with and without RA. In this study, the authors compare the morphological risk of VA injury relating to C-2 PS fixation in patients with and without RA.
METHODS: A total of 110 3D CT images of the cervical spine including the axis were evaluated. Fifty patients with RA and 60 patients without RA were included in the study. The maximum PS diameter (MPSD) that could be used at C-2 without breaching the cortex was measured in 3D using a computer-assisted navigation system. A narrow-pedicle carrier was defined as a patient with an MPSD of 4 mm or less.
RESULTS: In the RA group, 42 of 100 MPSDs were < or = 4 mm, and 30 of 50 patients (60%) were narrow-pedicle carriers. In the non-RA group, 10 of 120 MPSDs (8%) were < or = 4 mm, and 8 of 60 (13%) patients were narrow-pedicle carriers. The MPSD, the anteroposterior (AP) diameter of C-3, and the ratio of MPSD to the AP diameter of C-3 were significantly smaller in the RA group than in the non-RA group. Multiple logistic regression analysis showed that RA and narrow C-3 AP diameter were significant risk factors for a narrow-pedicle carrier.
CONCLUSIONS: Rheumatoid arthritis is a significant risk factor for a narrow C-2 pedicle. When performing PS placement at C-2, particularly in patients with RA, thorough preoperative evaluation of the bone architecture is very important for avoiding inadvertent injury to the VA.

Entities:  

Mesh:

Year:  2008        PMID: 18590406     DOI: 10.3171/SPI/2008/9/7/017

Source DB:  PubMed          Journal:  J Neurosurg Spine        ISSN: 1547-5646


  3 in total

1.  A multicenter study on accuracy and complications of freehand placement of cervical pedicle screws under lateral fluoroscopy in different pathological conditions: CT-based evaluation of more than 1,000 screws.

Authors:  Yoshihiro Hojo; Manabu Ito; Kota Suda; Itaru Oda; Hisashi Yoshimoto; Kuniyoshi Abumi
Journal:  Eur Spine J       Date:  2014-07-22       Impact factor: 3.134

2.  The reinforcement of a C2 laminar screw by a C2 laminar hook as an anchor of occipito-C2 fusion.

Authors:  Masashi Neo; Hiroyuki Yoshitomi; Mitsuru Takemoto; Masanori Izeki
Journal:  Eur J Orthop Surg Traumatol       Date:  2013-10-27

3.  The Surgical Treatment Principles of Atlantoaxial Instability Focusing on Rheumatoid Arthritis.

Authors:  Yu-Tung Shih; Ting-Hsien Kao; Hung-Chuan Pan; Hsien-Te Chen; Hsi-Kai Tsou
Journal:  Biomed Res Int       Date:  2015-07-26       Impact factor: 3.411

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.