Literature DB >> 1858664

The physiological cost of wearing a disposable respirator.

J G Jones1.   

Abstract

In order to gain an understanding of the physiological stresses imposed by the wearing of a single-use disposable respirator, a series of experiments was done to measure the cardiopulmonary effects of wearing the respirator (heart rate, respiratory rate, and blood pressure); resistance to breathing while wearing a respirator; and heat stress imposed by the use of a respirator (changes in inspired and expired air temperature). Ten men, ages 24 to 35, of varying fitness levels, served as volunteers in the studies. All the men exercised on a treadmill both with and without 3M Model 8715 disposable respirators. Workloads corresponding to light, moderate, and heavy levels were calculated for each volunteer based on his maximal oxygen uptake. As work intensity increased, an increase in breathing resistance was found. Peak resistances were in the range of +/- 2 cm water. Work-intensity level increases in respiratory rates were found with and without the respirators, but the respirator use trial had a significantly increased respiratory rate. Heart rate also showed a dose-related increase as work intensity increased and was significantly greater in the respirator trials at heavy levels of work and during recovery. Systolic blood pressure showed a biphasic response to respirator use, being significantly lower at rest and higher at high levels of work. Diastolic blood pressure changes were less dramatic but were elevated in the respirator trials. Clinically important increases in blood pressure were found in two volunteers when respirators were worn. Air temperatures immediately anterior to the face were, on average, 7.5 degrees C higher in the respirator trials.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1991        PMID: 1858664     DOI: 10.1080/15298669191364631

Source DB:  PubMed          Journal:  Am Ind Hyg Assoc J        ISSN: 0002-8894


  23 in total

1.  Exposure assessment for roofers exposed to silica during installation of roof tiles.

Authors:  Ronald M Hall; Chandran Achutan; Ron Sollberger; Robert E McCleery; Manuel Rodriguez
Journal:  J Occup Environ Hyg       Date:  2013       Impact factor: 2.155

2.  The effectiveness of respirators measured during styrene exposure in a plastic boat factory.

Authors:  A Löf; C Brohede; E Gullstrand; K Lindström; J Sollenberg; K Wrangskog; M Hagberg; B K Hedman
Journal:  Int Arch Occup Environ Health       Date:  1993       Impact factor: 3.015

3.  Effect of respirator resistance on tolerant capacity during graded load exercise.

Authors:  Man Qiu; Sheng Wang
Journal:  J Huazhong Univ Sci Technolog Med Sci       Date:  2012-06-09

Review 4.  What can individuals do to reduce personal health risks from air pollution?

Authors:  Robert Laumbach; Qingyu Meng; Howard Kipen
Journal:  J Thorac Dis       Date:  2015-01       Impact factor: 2.895

5.  Mask Use for Athletes: A Systematic Review of Safety and Performance Outcomes.

Authors:  Ariana Lott; Timothy Roberts; Cordelia W Carter
Journal:  Sports Health       Date:  2022-07-19       Impact factor: 4.355

6.  Impact of low filter resistances on subjective and physiological responses to filtering facepiece respirators.

Authors:  Raymond J Roberge; Jung-Hyun Kim; Jeffrey B Powell; Ronald E Shaffer; Caroline M Ylitalo; John M Sebastian
Journal:  PLoS One       Date:  2013-12-27       Impact factor: 3.240

7.  Effect of external airflow resistive load on postural and exercise-associated cardiovascular and pulmonary responses in pregnancy: a case control study.

Authors:  Jung-Hyun Kim; Raymond J Roberge; Jeffrey B Powell
Journal:  BMC Pregnancy Childbirth       Date:  2015-02-22       Impact factor: 3.007

8.  Pressure drop of filtering facepiece respirators: How low should we go?

Authors:  Jung-Hyun Kim; Raymond J Roberge; Jeffrey B Powell; Ronald E Shaffer; Caroline M Ylitalo; John M Sebastian
Journal:  Int J Occup Med Environ Health       Date:  2015       Impact factor: 1.843

9.  Heat stress evaluation of two-layer chemical demilitarization ensembles with a full face negative pressure respirator.

Authors:  Oclla Michele Fletcher; Ryan Guerrina; Candi D Ashley; Thomas E Bernard
Journal:  Ind Health       Date:  2014-04-05       Impact factor: 2.179

10.  Respiratory consequences of N95-type Mask usage in pregnant healthcare workers-a controlled clinical study.

Authors:  Pearl Shuang Ye Tong; Anita Sugam Kale; Kailyn Ng; Amelia Peiwen Loke; Mahesh Arjandas Choolani; Chin Leong Lim; Yiong Huak Chan; Yap Seng Chong; Paul Anantharajah Tambyah; Eu-Leong Yong
Journal:  Antimicrob Resist Infect Control       Date:  2015-11-16       Impact factor: 4.887

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.