Literature DB >> 18585935

Multidimensional characterization of carotid artery stenosis using CT imaging: a comparison with ultrasound grading and peak flow measurement.

J van Prehn1, B E Muhs, B Pramanik, M Ollenschleger, C B Rockman, N S Cayne, M A Adelman, G R Jacobowitz, T S Maldonado.   

Abstract

PURPOSE: Clinical decision making for carotid surgery depends largely upon stenosis grade. While digital subtraction angiography remains the gold standard for stenosis grading, many physicians use less invasive modalities. The purpose of this study was to compare the results of multidimensional Computed tomography (CTA) with ultrasound (US) grading and peak flow velocity (PSV).
METHODS: 37 stenosed carotid arteries were studied retrospectively in 36 consecutive patients. US grading and PSV were compared to multidimensional CTA analysis (diameter, area and volumetric measurements), performed by a medical software company. Calculations of stenosis percentage on CTA were made using the NASCET and ECST methodology. Diameter measurements were also performed by a neuroradiologist.
RESULTS: All CTA diameter, area and volume measurements had only modest correlation with PSV (r<0.5) and ultrasound grading (p<0.5). There was concordant classification of stenosis grades in only 40-60% of cases. CTA diameter, area and volume measurements had good correlation (0.69<r<0.87) with one another using ECST methodology. Using NASCET methodology on CTA, correlation between diameter and area was insignificant (r=0.32). CTA volumetric analysis with the NASCET method yielded 27 negative stenosis grades. Repeatability coefficient for selecting the normal distal ICA 20 mm more distally was 20% for diameter and 43% for area. CTA diameter interobserver repeatability coefficients were 22.9% (NASCET) and 17.8% (ECST) and 0.7 mm (lumen) and 1.9 mm (vessel).
CONCLUSIONS: All CTA measurements showed moderate correlation with both ultrasound grading and PSV. Selection of the level of the normal distal ICA influences the NASCET calculations and can produce discrepant stenosis grades. Multidimensional CTA analysis seems to have no additional value for stenosis grading, but provides other useful anatomic information.

Entities:  

Mesh:

Year:  2008        PMID: 18585935     DOI: 10.1016/j.ejvs.2008.04.016

Source DB:  PubMed          Journal:  Eur J Vasc Endovasc Surg        ISSN: 1078-5884            Impact factor:   7.069


  6 in total

Review 1.  Concordance rates of Doppler ultrasound and CT angiography in the grading of carotid artery stenosis: a systematic literature review.

Authors:  Chiara Zavanone; Emma Ragone; Yves Samson
Journal:  J Neurol       Date:  2011-11-08       Impact factor: 4.849

2.  Multi-parametric ultrasound criteria for internal carotid artery disease-comparison with CT angiography.

Authors:  Kristian Barlinn; Thomas Floegel; Hagen H Kitzler; Jessica Kepplinger; Timo Siepmann; Lars-Peder Pallesen; Ulf Bodechtel; Heinz Reichmann; Andrei V Alexandrov; Volker Puetz
Journal:  Neuroradiology       Date:  2016-05-26       Impact factor: 2.804

Review 3.  Duplex ultrasound for diagnosing symptomatic carotid stenosis in the extracranial segments.

Authors:  Nicolle Cassola; Jose Cc Baptista-Silva; Luis Cu Nakano; Carolina Dq Flumignan; Ricardo Sesso; Vladimir Vasconcelos; Nelson Carvas Junior; Ronald Lg Flumignan
Journal:  Cochrane Database Syst Rev       Date:  2022-07-11

4.  Grading of carotid artery stenosis with computed tomography angiography: whether to use the narrowest diameter or the cross-sectional area.

Authors:  Kristina Samarzija; Petar Milosevic; Zoran Jurjevic; Emilija Erdeljac
Journal:  Insights Imaging       Date:  2018-05-24

5.  COMPARISON OF CAROTID STENOSIS GRADING BY CT ANGIOGRAPHY AND DOPPLER ULTRASONOGRAPHY: HOW THE STATISTICAL METHODS APPLIED INFLUENCE THE RESULTS.

Authors:  Kristina Samaržija; Petar Milošević; Zoran Jurjević; Emilija Erdeljac
Journal:  Acta Clin Croat       Date:  2022-02       Impact factor: 0.780

6.  Correlation between US-PSV and 64-Row MDCTA with Advanced Vessel Analysis in the Quantification of 50-70% Carotid Artery Stenosis.

Authors:  Matteo Stefanini; Eleonora Gaspari; Luca Boi; Costantino Del Giudice; Roberta Mastrangeli; Francesca Nucera; Giovanni Simonetti
Journal:  Int J Vasc Med       Date:  2012-04-22
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.