Literature DB >> 18585153

Determination of 3-MCPD by GC-MS/MS with PTV-LV injector used for a survey of Spanish foodstuffs.

Nuria León1, Vicent Yusà, Olga Pardo, Agustín Pastor.   

Abstract

3-Monochloropropane-1,2-diol (3-MCPD) is the most common chemical contaminant of the group of chloropropanols. It can occur in foods and food ingredients at low levels as a result of processing, migration from packaging materials during storage and domestic cooking. A sensitive method for determination of 3-MCPD in foodstuffs using programmable temperature vaporization (PTV) with large-volume injection (LVI) gas chromatography (GC) with tandem mass spectrometry detection (MS/MS) has been developed and optimized. The optimization of the injection and detection parameters was carried out using statistical experimental design. A Plackett-Burman design was used to estimate the influence of resonance excitation voltage (REV), isolation time (IT), excitation time (ET), ion source temperature (IST), and electron energy (EE) on the analytical response in the ion trap mass spectrometer (ITMS). Only REV was found to have a statically significant effect. On the other hand, a central composite design was used to optimize the settings of injection temperature (T(inlet)), vaporization temperature (T(vap)), vaporization time (t(vap)) and flow (Flow). The optimized method has an instrumental limit of detection (signal-to-noise ratio 3:1) of 0.044 ng mL(-1). From Valencian, Spain, supermarkets 94 samples of foods were surveyed for 3-MCPD. Using the optimized method levels higher than the limit established for soy sauce by the European Union were found in some samples. The estimated daily intake of 3-MCPD throughout the investigated foodstuffs for adults and children was found about 0.005 and 0.01%, respectively, of the established provisional tolerable daily intake.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 18585153     DOI: 10.1016/j.talanta.2007.12.028

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  2 in total

1.  Mass spectrometry parameters optimization for the 46 multiclass pesticides determination in strawberries with gas chromatography ion-trap tandem mass spectrometry.

Authors:  Virgínia C Fernandes; Jose L Vera; Valentina F Domingues; Luís M S Silva; Nuno Mateus; Cristina Delerue-Matos
Journal:  J Am Soc Mass Spectrom       Date:  2012-09-20       Impact factor: 3.109

Review 2.  Optimizing Mass Spectrometry Analyses: A Tailored Review on the Utility of Design of Experiments.

Authors:  Elizabeth S Hecht; Ann L Oberg; David C Muddiman
Journal:  J Am Soc Mass Spectrom       Date:  2016-03-07       Impact factor: 3.109

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.