Literature DB >> 18584098

Light-actuated high pressure-resisting microvalve for on-chip flow control based on thermo-responsive nanostructured polymer.

Guofang Chen1, Frantisek Svec, Daniel R Knapp.   

Abstract

A simple light-actuated microvalve using a quartz halogen illuminator with tungsten filament was introduced to manipulate flow path effectively in micro-total analysis systems, which reduces system complexity and the need for on-chip integration. The microvalve device in cyclic olefin copolymer (COC) microchip functions very well based on the thermo-responsive polymer, poly(N-isopropylacrylamide) (PNIPAAm), whose pressure-tolerance can be tuned by changing the mechanical strength of polymer monolith inside the microchannel with the choice of suitable amount of monomer and crosslinker. The response time and pressure resistance of the valve can be optimized by the tetrahydrofuran composition in the polymerization mixture as well. Very importantly, the microvalve can withstand the leakage pressure up to around 1350 psi, and its opening and closing response time is only 4.0 and 6.2 s respectively. Microchips with such valves will be very useful in drug delivery, chemical analysis and proteomic analysis.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18584098     DOI: 10.1039/b803293a

Source DB:  PubMed          Journal:  Lab Chip        ISSN: 1473-0189            Impact factor:   6.799


  13 in total

1.  Optofluidic membrane interferometer: An imaging method for measuring microfluidic pressure and flow rate simultaneously on a chip.

Authors:  Wuzhou Song; Demetri Psaltis
Journal:  Biomicrofluidics       Date:  2011-11-30       Impact factor: 2.800

2.  Single-use thermoplastic microfluidic burst valves enabling on-chip reagent storage.

Authors:  Omid D Rahmanian; Don L DeVoe
Journal:  Microfluid Nanofluidics       Date:  2015-05-01       Impact factor: 2.529

3.  Flow-through immunosensors using antibody-immobilized polymer monoliths.

Authors:  Jikun Liu; Chien-Fu Chen; Chih-Wei Chang; Don L DeVoe
Journal:  Biosens Bioelectron       Date:  2010-06-11       Impact factor: 10.618

4.  Role of Mechanical Factors in Applications of Stimuli-Responsive Polymer Gels - Status and Prospects.

Authors:  Alexander V Goponenko; Yuris A Dzenis
Journal:  Polymer (Guildf)       Date:  2016-08-24       Impact factor: 4.430

5.  Nanoparticle-functionalized porous polymer monolith detection elements for surface-enhanced Raman scattering.

Authors:  Jikun Liu; Ian White; Don L DeVoe
Journal:  Anal Chem       Date:  2011-02-15       Impact factor: 6.986

6.  Use of vacuum bagging for fabricating thermoplastic microfluidic devices.

Authors:  Christopher L Cassano; Andrew J Simon; Wei Liu; Carl Fredrickson; Z Hugh Fan
Journal:  Lab Chip       Date:  2015-01-07       Impact factor: 6.799

7.  Flow manipulation and cell immobilization for biochemical applications using thermally responsive fluids.

Authors:  Anil Haraksingh Thilsted; Vahid Bazargan; Nina Piggott; Vivien Measday; Boris Stoeber
Journal:  Biomicrofluidics       Date:  2012-11-28       Impact factor: 2.800

8.  Use of photopatterned porous polymer monoliths as passive micromixers to enhance mixing efficiency for on-chip labeling reactions.

Authors:  Dieudonne A Mair; Thomas R Schwei; Theresa S Dinio; Frantisek Svec; Jean M J Fréchet
Journal:  Lab Chip       Date:  2009-01-07       Impact factor: 6.799

9.  Microfluidic-integrated laser-controlled microactuators with on-chip microscopy imaging functionality.

Authors:  Jae Hee Jung; Chao Han; Seung Ah Lee; Jinho Kim; Changhuei Yang
Journal:  Lab Chip       Date:  2014-10-07       Impact factor: 6.799

10.  Polydimethylsiloxane-based conducting composites and their applications in microfluidic chip fabrication.

Authors:  Xiuqing Gong; Weijia Wen
Journal:  Biomicrofluidics       Date:  2009-03-23       Impact factor: 2.800

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.