A 3D pencil-beam-based superposition algorithm for photon dose calculation in heterogeneous media.

L Tillikainen1, H Helminen, T Torsti, S Siljamäki, J Alakuijala, J Pyyry, W Ulmer.   

Abstract

In this work, a novel three-dimensional superposition algorithm for photon dose calculation is presented. The dose calculation is performed as a superposition of pencil beams, which are modified based on tissue electron densities. The pencil beams have been derived from Monte Carlo simulations, and are separated into lateral and depth-directed components. The lateral component is modeled using exponential functions, which allows accurate modeling of lateral scatter in heterogeneous tissues. The depth-directed component represents the total energy deposited on each plane, which is spread out using the lateral scatter functions. Finally, convolution in the depth direction is applied to account for tissue interface effects. The method can be used with the previously introduced multiple-source model for clinical settings. The method was compared against Monte Carlo simulations in several phantoms including lung- and bone-type heterogeneities. Comparisons were made for several field sizes for 6 and 18 MV energies. The deviations were generally within (2%, 2 mm) of the field central axis d(max). Significantly larger deviations (up to 8%) were found only for the smallest field in the lung slab phantom for 18 MV. The presented method was found to be accurate in a wide range of conditions making it suitable for clinical planning purposes.

Mesh:

Substances:

Year:  2008        PMID: 18583728     DOI: 10.1088/0031-9155/53/14/008

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  35 in total

1.  Dosimetric verification of the anisotropic analytical algorithm in lung equivalent heterogeneities with and without bone equivalent heterogeneities.

Authors:  Kaoru Ono; Satoru Endo; Kenichi Tanaka; Masaharu Hoshi; Yutaka Hirokawa
Journal:  Med Phys       Date:  2010-08       Impact factor: 4.071

2.  Accuracy of out-of-field dose calculations by a commercial treatment planning system.

Authors:  Rebecca M Howell; Sarah B Scarboro; S F Kry; Derek Z Yaldo
Journal:  Phys Med Biol       Date:  2010-11-12       Impact factor: 3.609

3.  Parallel beamlet dose calculation via beamlet contexts in a distributed multi-GPU framework.

Authors:  Ryan Neph; Cheng Ouyang; John Neylon; Youming Yang; Ke Sheng
Journal:  Med Phys       Date:  2019-06-30       Impact factor: 4.071

4.  On the dosimetric impact of inhomogeneity management in the Acuros XB algorithm for breast treatment.

Authors:  Antonella Fogliata; Giorgia Nicolini; Alessandro Clivio; Eugenio Vanetti; Luca Cozzi
Journal:  Radiat Oncol       Date:  2011-08-26       Impact factor: 3.481

5.  Comparison between Acuros XB and Brainlab Monte Carlo algorithms for photon dose calculation.

Authors:  M Mißlbeck; P Kneschaurek
Journal:  Strahlenther Onkol       Date:  2012-04-12       Impact factor: 3.621

6.  Dosimetric comparison of Acuros XB deterministic radiation transport method with Monte Carlo and model-based convolution methods in heterogeneous media.

Authors:  Tao Han; Justin K Mikell; Mohammad Salehpour; Firas Mourtada
Journal:  Med Phys       Date:  2011-05       Impact factor: 4.071

7.  Dosimetric impact of Acuros XB on cervix radiotherapy using RapidArc technique: a dosimetric study.

Authors:  Lalit Kumar; Vimal Kishore; Manindra Bhushan; Pawan Kumar; Rahul Lal Chaudhary
Journal:  Rep Pract Oncol Radiother       Date:  2021-08-12

8.  On the quantification of the dosimetric accuracy of collapsed cone convolution superposition (CCCS) algorithm for small lung volumes using IMRT.

Authors:  Oscar I Calvo; Alonso N Gutiérrez; Sotirios Stathakis; Carlos Esquivel; Nikos Papanikolaou
Journal:  J Appl Clin Med Phys       Date:  2012-05-10       Impact factor: 2.102

9.  A depth dose study between AAA and AXB algorithm against Monte Carlo simulation using AIP CT of a 4D dataset from a moving phantom.

Authors:  Roger Cai Xiang Soh; Guan Heng Tay; Wen Siang Lew; James Cheow Lei Lee
Journal:  Rep Pract Oncol Radiother       Date:  2018-09-03

10.  The dosimetric impact of respiratory breast movement and daily setup error on tangential whole breast irradiation using conventional wedge, field-in-field and irregular surface compensator techniques.

Authors:  Tomohisa Furuya; Satoru Sugimoto; Chie Kurokawa; Shuichi Ozawa; Kumiko Karasawa; Keisuke Sasai
Journal:  J Radiat Res       Date:  2012-08-01       Impact factor: 2.724

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.