Literature DB >> 18582887

The new proximal femoral nail antirotation (PFNA) in daily practice: results of a multicentre clinical study.

R K J Simmermacher1, J Ljungqvist, H Bail, T Hockertz, A J H Vochteloo, U Ochs, Chr v d Werken.   

Abstract

The treatment of unstable trochanteric femoral fractures is still challenging. The ideal implant should be easy to handle, allow for immediate full weight-bearing postoperatively and should have sufficient purchase in the femoral head/neck-fragment to limit cut-outs due to varus-deviation and rotation. The proximal femoral nail antirotation (PFNA), designed by AO, is an intramedullary device with a helical blade rather than a screw for better purchase in the femoral head and was tested in a clinical study. Consecutive patients with unstable trochanteric fractures (AO-classification 31.A.2 and A.3 only) were included and followed for 1 year. Primary objectives were assessment of operative and postoperative complications, whereas secondary objectives included surgical details, general complications and final outcome measurements. In 11 European clinics, 315 patients were included and treated with a PFNA. Almost all fractures healed within 6 months. Fifty-six percent of the patients regained the pre-trauma mobility and 18% died within the follow-up period. Forty-six implant-related complications--leading to 28 unplanned re-operations--were recorded, with four acetabular penetrations (three of which were after a new fall on that hip) and seven ipsilateral femoral shaft fractures as the most serious ones. As the joint-penetrations did not resemble the cut-out seen with other implants it is concluded that the PFNA--due to its helical blade--possibly limits the effects of early rotation of the head/neck-fragment in unstable trochanteric fractures and therefore seems currently to be the optimal implant for the treatment of these fractures especially in osteoporotic bone.

Entities:  

Mesh:

Year:  2008        PMID: 18582887     DOI: 10.1016/j.injury.2008.02.005

Source DB:  PubMed          Journal:  Injury        ISSN: 0020-1383            Impact factor:   2.586


  70 in total

1.  Is helical blade nailing superior to locked minimally invasive plating in unstable pertrochanteric fractures?

Authors:  Matthias Knobe; Wolf Drescher; Nicole Heussen; Richard Martin Sellei; Hans-Christoph Pape
Journal:  Clin Orthop Relat Res       Date:  2012-02-07       Impact factor: 4.176

2.  Prospective randomised study comparing screw versus helical blade in the treatment of low-energy trochanteric fractures.

Authors:  Richard Stern; Anne Lübbeke; Domizio Suva; Hermes Miozzari; Pierre Hoffmeyer
Journal:  Int Orthop       Date:  2011-03-10       Impact factor: 3.075

3.  A comparison of two fixation methods for femoral trochanteric fractures: a new generation intramedullary system vs sliding hip screw.

Authors:  Christian Carulli; Federico Piacentini; Tommaso Paoli; Roberto Civinini; Massimo Innocenti
Journal:  Clin Cases Miner Bone Metab       Date:  2017-05-30

4.  Proximal femoral nail antirotation against dynamic hip screw for unstable trochanteric fractures; a prospective randomized comparison.

Authors:  Sinan Zehir; R Zehir; Sultan Zehir; İ Azboy; N Haykir
Journal:  Eur J Trauma Emerg Surg       Date:  2014-10-31       Impact factor: 3.693

5.  Is helical blade superior to screw design in terms of cut-out rate for elderly trochanteric fractures? A meta-analysis of randomized controlled trials.

Authors:  Xiao Huang; Frankie Leung; Ming Liu; Long Chen; Zhao Xu; Zhou Xiang
Journal:  Eur J Orthop Surg Traumatol       Date:  2014-02-21

6.  3066 consecutive Gamma Nails. 12 years experience at a single centre.

Authors:  Alicja J Bojan; Claudia Beimel; Andreas Speitling; Gilbert Taglang; Carl Ekholm; Anders Jönsson
Journal:  BMC Musculoskelet Disord       Date:  2010-06-26       Impact factor: 2.362

Review 7.  Intertrochanteric fractures: a review of fixation methods.

Authors:  Senthil Nathan Sambandam; Jayadev Chandrasekharan; Varatharaj Mounasamy; Cyril Mauffrey
Journal:  Eur J Orthop Surg Traumatol       Date:  2016-03-30

8.  Unstable intertrochanteric femur fractures: is there a consensus on definition and treatment in Germany?

Authors:  Matthias Knobe; Gertraud Gradl; Andreas Ladenburger; Ivan S Tarkin; Hans-Christoph Pape
Journal:  Clin Orthop Relat Res       Date:  2013-09       Impact factor: 4.176

9.  Distal locked and unlocked nailing for perthrochanteric fractures--a prospective comparative randomized study.

Authors:  Xing Li; Liping Zhang; Zhiyong Hou; Zhao Meng; Wei Chen; Pengcheng Wang; Yingze Zhang
Journal:  Int Orthop       Date:  2015-04-26       Impact factor: 3.075

10.  A comparative biomechanical study of proximal femoral nail (InterTAN) and proximal femoral nail antirotation for intertrochanteric fractures.

Authors:  Yanfeng Huang; Chunlin Zhang; Yi Luo
Journal:  Int Orthop       Date:  2013-10-05       Impact factor: 3.075

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.