Literature DB >> 1858218

An efficient algorithm to remove low frequency Doppler signals in digital Doppler systems.

A P Hoeks1, J J van de Vorst, A Dabekaussen, P J Brands, R S Reneman.   

Abstract

In color flow imaging, a high flow map rate in combination with a reasonable width of the map and good velocity resolution is essential to properly appreciate the time-dependent phenomena. The velocity resolution depends on the length of the signal segment considered in combination with the settling time of the high pass filter used to eliminate transients and low frequency artifacts. The latter can be reduced by appropriate processing. This paper presents an algorithm to suppress low frequency Doppler signals effectively and efficiently, while all the data points within the segment considered contribute equally to the average Doppler frequency computed. The algorithm is applied to computer generated Doppler signals to evaluate their time and frequency behavior. It is concluded that the proposed scheme functions adequately under various signal conditions.

Mesh:

Year:  1991        PMID: 1858218     DOI: 10.1177/016173469101300202

Source DB:  PubMed          Journal:  Ultrason Imaging        ISSN: 0161-7346            Impact factor:   1.578


  5 in total

1.  Doppler ultrasound wall removal based on the spatial correlation of wavelet coefficients.

Authors:  Dawei Jin; Yuanyuan Wang
Journal:  Med Biol Eng Comput       Date:  2007-08-08       Impact factor: 2.602

2.  Vibrating interventional device detection using real-time 3-D color Doppler.

Authors:  Matthew P Fronheiser; Salim F Idriss; Patrick D Wolf; Stephen W Smith
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2008       Impact factor: 2.725

Review 3.  Developments in cardiovascular ultrasound: Part 1: Signal processing and instrumentation.

Authors:  P J Fish; P R Hoskins; C Moran; W N McDicken
Journal:  Med Biol Eng Comput       Date:  1997-11       Impact factor: 2.602

4.  Independent Component-Based Spatiotemporal Clutter Filtering for Slow Flow Ultrasound.

Authors:  Jaime Tierney; Jennifer Baker; Daniel Brown; Don Wilkes; Brett Byram
Journal:  IEEE Trans Med Imaging       Date:  2019-11-04       Impact factor: 10.048

Review 5.  Clutter suppression in ultrasound: performance evaluation and review of low-rank and sparse matrix decomposition methods.

Authors:  Naiyuan Zhang; Md Ashikuzzaman; Hassan Rivaz
Journal:  Biomed Eng Online       Date:  2020-05-28       Impact factor: 2.819

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.