| Literature DB >> 18581417 |
Peter Brunecker1, Matthias Endres, Christian H Nolte, Jörg Schultze, Susanne Wegener, Gerhard Jan Jungehülsing, Bianca Müller, Christian M Kerskens, Jochen B Fiebach, Arno Villringer, Jens Steinbrink.
Abstract
For longitudinal studies in patients suffering from cerebrovascular diseases the poor reproducibility of perfusion measurements via dynamic susceptibility-weighted contrast-enhanced MRI (DSC-MRI) is a relevant concern. We evaluate a novel algorithm capable of overcoming limitations in DSC-MRI caused by partial volume and saturation issues in the arterial input function (AIF) by a blood flow stimulation-study. In 21 subjects, perfusion parameters before and after administration of blood flow stimulating L-arginine were calculated utilizing a block-circulant singular value decomposition (cSVD). A total of two different raters and three different rater conditions were employed to select AIFs: Besides 1) an AIF selection by an experienced rater, a beginner rater applied a steady state-oriented strategy, returning; 2) raw; and 3) corrected AIFs. Highly significant changes in regional cerebral blood flow (rCBF) by 9.0% (P < 0.01) could only be found when the AIF correction was performed. To further test for improved reproducibility, in a subgroup of seven subjects the baseline measurement was repeated 6 weeks after the first examination. In this group as well, using the correction algorithm decreased the SD of the difference between the two baseline measurements by 42%. (c) 2008 Wiley-Liss, Inc.Entities:
Mesh:
Substances:
Year: 2008 PMID: 18581417 DOI: 10.1002/mrm.21612
Source DB: PubMed Journal: Magn Reson Med ISSN: 0740-3194 Impact factor: 4.668