Literature DB >> 18581389

Reducing morphological variability of the cervical carotid artery in serial magnetic resonance imaging using a head and neck immobilization device.

Brian E Chapman1, Emilee S Minalga, Christopher Brown, John A Roberts, J Rock Hadley.   

Abstract

PURPOSE: To evaluate how well a head and neck immobilization device performed in reducing lumen morphology variability in repeated MR imaging of the carotid artery.
MATERIALS AND METHODS: Quantitative measures of lumen and plaque characteristics may be important for longitudinal management of carotid atherosclerotic disease. However, quantitative measurements of the carotid artery are limited by their dependence on patient positioning, which can be quite variable. We created a head and neck immobilization device to reduce the variability of patient positioning during MR imaging of the carotid artery. In this article we describe the design and use of the immobilization device and assess how well its use reduced variability in vascular orientation and measurements of the carotid lumen cross-sectional area. Evaluation was based on 15 subjects who were repeatedly imaged without the immobilization device and 14 subjects who were repeatedly imaged with the device.
RESULTS: Use of the immobilization device decreased the orientation variability from 9.1 degrees to 5.3 degrees (P = 0.0006) and the variability (defined as the standard deviation divided by the mean) of the cross-sectional area decreased from 0.24 to 0.18 (P = 0.04).
CONCLUSION: Using the immobilization device effectively reduces variability in repeated imaging of the carotid arteries. (c) 2008 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2008        PMID: 18581389     DOI: 10.1002/jmri.21404

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  3 in total

1.  Interchangeable neck shape-specific coils for a clinically realizable anterior neck phased array system.

Authors:  Michael J Beck; Dennis L Parker; Bradley D Bolster; Seong-Eun Kim; J Scott McNally; Gerald S Treiman; J Rock Hadley
Journal:  Magn Reson Med       Date:  2017-02-10       Impact factor: 4.668

2.  Single-scan dual-tracer FLT+FDG PET tumor characterization.

Authors:  Dan J Kadrmas; Thomas C Rust; John M Hoffman
Journal:  Phys Med Biol       Date:  2013-01-08       Impact factor: 3.609

3.  Vitamin D and Vulnerable Carotid Plaque.

Authors:  J S McNally; T M Burton; B W Aldred; S-E Kim; M S McLaughlin; L B Eisenmenger; G J Stoddard; J J Majersik; D V Miller; G S Treiman; D L Parker
Journal:  AJNR Am J Neuroradiol       Date:  2016-06-16       Impact factor: 3.825

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.