Literature DB >> 18581326

Acquisition-weighted stack of spirals for fast high-resolution three-dimensional ultra-short echo time MR imaging.

Yongxian Qian1, Fernando E Boada.   

Abstract

Ultra-short echo time (UTE) MRI requires both short excitation ( approximately 0.5 ms) and short acquisition delay (<0.2 ms) to minimize T(2)-induced signal decay. These requirements currently lead to low acquisition efficiency when high resolution (<1 mm) is pursued. A novel pulse sequence, acquisition-weighted stack of spirals (AWSOS), is proposed here to acquire high-resolution three-dimensional (3D) UTE images with short scan time ( approximately 72 s). The AWSOS sequence uses variable-duration slice encoding to minimize T(2) decay, separates slice thickness from in-plane resolution to reduce the number of slice encodings, and uses spiral trajectories to accelerate in-plane data collections. T(2)- and off-resonance induced slice widening and image blurring were calculated from 1.5 to 7 Tesla (T) through point spread function. Computer simulations were performed to optimize spiral interleaves and readout times. Phantom scans and in vivo experiments on human heads were implemented on a clinical 1.5T scanner (G(max) = 40 mT/m, S(max) = 150 T/m/s). Accounting for the limits on B(1) maximum, specific absorption rate (SAR), and the lowered amplitude of slab-select gradient, a sinc radiofrequency (RF) pulse of 0.8ms duration and 1.5 cycles was found to produce a flat slab profile. High in-plane resolution (0.86 mm) images were obtained for the human head using echo time (TE) = 0.608 ms and total shots = 720 (30 slice-encodings x 24 spirals). Compared with long-TE (10 ms) images, the ultrashort-TE AWSOS images provided clear visualization of short-T(2) tissues such as the nose cartilage, the eye optic nerve, and the brain meninges and parenchyma. (c) 2008 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2008        PMID: 18581326     DOI: 10.1002/mrm.21620

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  40 in total

1.  High-resolution sodium imaging of human brain at 7 T.

Authors:  Yongxian Qian; Tiejun Zhao; Hai Zheng; Jonathan Weimer; Fernando E Boada
Journal:  Magn Reson Med       Date:  2011-12-05       Impact factor: 4.668

2.  Preserving the accuracy and resolution of the sodium bioscale from quantitative sodium MRI during intrasubject alignment across longitudinal studies.

Authors:  Ian C Atkinson; Aiming Lu; Keith R Thulborn
Journal:  Magn Reson Med       Date:  2011-12-02       Impact factor: 4.668

3.  Review. The Agfa Mayneord lecture: MRI of short and ultrashort T₂ and T₂* components of tissues, fluids and materials using clinical systems.

Authors:  G M Bydder
Journal:  Br J Radiol       Date:  2011-12       Impact factor: 3.039

4.  UTE-T2∗ mapping detects sub-clinical meniscus injury after anterior cruciate ligament tear.

Authors:  A Williams; Y Qian; S Golla; C R Chu
Journal:  Osteoarthritis Cartilage       Date:  2012-01-18       Impact factor: 6.576

5.  Assessment of Silent T1-weighted head imaging at 7 T.

Authors:  Mauro Costagli; Mark R Symms; Lorenzo Angeli; Douglas A C Kelley; Laura Biagi; Andrea Farnetani; Catarina Rua; Graziella Donatelli; Gianluigi Tiberi; Michela Tosetti; Mirco Cosottini
Journal:  Eur Radiol       Date:  2015-08-29       Impact factor: 5.315

6.  High-resolution ultrashort echo time (UTE) imaging on human knee with AWSOS sequence at 3.0 T.

Authors:  Yongxian Qian; Ashley A Williams; Constance R Chu; Fernando E Boada
Journal:  J Magn Reson Imaging       Date:  2011-10-14       Impact factor: 4.813

7.  UTE-T2∗ mapping of human articular cartilage in vivo: a repeatability assessment.

Authors:  A Williams; Y Qian; C R Chu
Journal:  Osteoarthritis Cartilage       Date:  2010-10-28       Impact factor: 6.576

8.  [Orbita - anatomy, development and deformities].

Authors:  K M Hartmann; M Golinski; A C Schröder; W Reith
Journal:  Radiologe       Date:  2008-12       Impact factor: 0.635

Review 9.  Measurement techniques for magnetic resonance imaging of fast relaxing nuclei.

Authors:  Simon Konstandin; Armin M Nagel
Journal:  MAGMA       Date:  2013-07-24       Impact factor: 2.310

10.  Repeatability of ultrashort echo time-based two-component T2* measurements on cartilages in human knee at 3 T.

Authors:  Yongxian Qian; Ashley A Williams; Constance R Chu; Fernando E Boada
Journal:  Magn Reson Med       Date:  2012-10-03       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.