Literature DB >> 18581094

Magnetic force-assisted meniscal resection under arthroscopy.

Takeo Yukawa1, Mitsuo Ochi, Takaaki Kobayashi, Nobuo Adachi, Mitsuhiro Nakamura, Kiyotaka Yamada.   

Abstract

Arthroscopic meniscectomy has become a standard procedure for a complete discoid meniscus or for displacement of a meniscal bucket handle tear, although it is not always easy due to poor visualization of the cutting portion. The purpose of this study is to examine whether meniscal resection can be easily carried out in a swine model using the magnetic force-assisted procedure, whereby a metal clip is attached to the meniscal flap and moved by an external magnetic force. Four fresh-frozen porcine lower extremities were used (age range: about 6 months). After opening the knee joint, a flap tear in the medial and lateral menisci was created. Then a metal clip was attached to the edge of the tear. With 20 cm distance between the knee and the disk of the external magnetic device, the flap was observed under arthroscopy. At the highest magnitude of 0.6 T, the direction of the magnetic field was changed. As the direction of the magnetic field was changed to move laterally, medially, up, and down, so the edge of the meniscal flap was observed to move in corresponding directions. Thanks to now having a clear view of the cutting portion, it was evident that meniscal resection could be easily carried out. Although we need to develop special instruments such as Titanium scissors and forceps and an external magnet system for surgery, the current study may be the first step towards a new era in the field of magnet-assisted arthroscopy.

Entities:  

Mesh:

Year:  2008        PMID: 18581094     DOI: 10.1007/s00167-008-0574-2

Source DB:  PubMed          Journal:  Knee Surg Sports Traumatol Arthrosc        ISSN: 0942-2056            Impact factor:   4.342


  4 in total

1.  Novel, magnetically guided catheter for endocardial mapping and radiofrequency catheter ablation.

Authors:  Mitchell N Faddis; Walter Blume; Jennifer Finney; Andrew Hall; John Rauch; Jon Sell; Kyongtae Ty Bae; Michael Talcott; Bruce Lindsay
Journal:  Circulation       Date:  2002-12-03       Impact factor: 29.690

2.  Magnetic anchor for more effective endoscopic mucosal resection.

Authors:  Toshiaki Kobayashi; Takushi Gotohda; Katsunori Tamakawa; Hirohisa Ueda; Tadao Kakizoe
Journal:  Jpn J Clin Oncol       Date:  2004-03       Impact factor: 3.019

3.  A new technique for arthroscopic resection of a bucket handle tear.

Authors:  N Paksima; B Ceccarelli; A Vitols
Journal:  Arthroscopy       Date:  1998 Jul-Aug       Impact factor: 4.772

4.  A novel cell delivery system using magnetically labeled mesenchymal stem cells and an external magnetic device for clinical cartilage repair.

Authors:  Takaaki Kobayashi; Mitsuo Ochi; Shinobu Yanada; Masakazu Ishikawa; Nobuo Adachi; Masataka Deie; Koji Arihiro
Journal:  Arthroscopy       Date:  2007-11-28       Impact factor: 4.772

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.