Literature DB >> 18580336

Magnetic resonance-guided angioplasty with delivery of contrast-media doped solutions to the vessel wall: an experimental study in swine.

Gabriele A Krombach1, Martin Wehner, Alberto Perez-Bouza, Linda Kaimann, Sylvia Kinzel, Thorsten Plum, Daniel Schibur, Michael Friebe, Rolf W Günther, Christian Hohl.   

Abstract

OBJECTIVES: To assess the feasibility of magnetic resonance (MR)-guided delivery of a solution containing contrast-medium and immediate online monitoring of its distribution to the vessel wall during MR-guided angioplasty in peripheral arteries.
MATERIALS AND METHODS: In 3 pigs, the feasibility of MR-guided atraumatic delivery of a solution containing contrast-medium and tissue dye (0.05 mmol/mL Gd-DTPA, 3% Evans blue dye) into the vessel wall of the iliac arteries was tested using a permeable balloon catheter (8 mm). Catheter placement was monitored using a steady-state free precession real-time imaging sequence.Additionally, in 5 pigs, surgically created bilateral stenoses in the external iliac artery were dilatated with the porous balloon. In these animals, contrast-enhanced MR angiography was performed before and after the interventions to assess the degree of the stenosis. In all animals, the vessel wall was delineated before and after dilatation using a T1-weighted gradient echo (GE) sequence.
RESULTS: In the 3 animals without stenosis, contrast medium was successfully applied to the vessel wall. On the GE images, the normalized signal intensity of the vessel wall was 0.95 +/- 0.015 arbitrary units (a. u.) prior and 2.15 +/- 0.105 a. u. after the intervention (P < 0.01). In the animals with stenosis, MR angiography performed before and after the intervention demonstrated successful dilatation of 9 of the 10 stenoses. Before the intervention, 7 stenoses were severe (76%-99%) and 3 moderate (50%-75%), and after the intervention, 4 stenoses were completely removed and 5 mild (<50%). Also in these 5 animals, the solution was visible in the vessel wall of the arteries on the T1-weighted GE MR images (normalized signal intensity prior the intervention 1.33 +/- 0.16 a. u. and 2.97 +/- 0.23 after angioplasty; P < 0.05). Histology demonstrated the distribution of the Evan's blue dye within the vessel wall in all animals.
CONCLUSIONS: MR-guided delivery of a contrast-medium containing solution and immediate online assessment of its distribution to the vessel wall during angioplasty in peripheral arteries is feasible.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18580336     DOI: 10.1097/RLI.0b013e31817ee519

Source DB:  PubMed          Journal:  Invest Radiol        ISSN: 0020-9996            Impact factor:   6.016


  2 in total

1.  MR imaging of hydrogel filament embolic devices loaded with superparamagnetic iron oxide or gadolinium.

Authors:  Monika Killer; Edward M Keeley; Gregory M Cruise; Anne Schmitt; Mark R McCoy
Journal:  Neuroradiology       Date:  2010-07-13       Impact factor: 2.804

2.  3.0-T MR imaging of intracoronary local delivery of motexafin gadolinium into coronary artery walls.

Authors:  Yanfeng Meng; Jinnan Wang; Jihong Sun; Feng Zhang; Patrick Willis; Jiakai Li; Han Wang; Tong Zhang; Stephanie Soriano; Bensheng Qiu; Xiaoming Yang
Journal:  Radiology       Date:  2013-03-19       Impact factor: 11.105