Literature DB >> 18580172

Randomized prospective study comparing the laryngeal tube suction II with the ProSeal laryngeal mask airway in anesthetized and paralyzed patients.

Tatsuaki Kikuchi1, Yoshinori Kamiya, Tsuyoshi Ohtsuka, Tomoko Miki, Takahisa Goto.   

Abstract

BACKGROUND: The Laryngeal Tube Suction II (LTSII; VBM, Medizintechnik, Sulz, Germany) is a recent revision of the Laryngeal Tube Suction. This study compared insertion and ventilation profiles of the LTSII and the ProSeal Laryngeal Mask Airway (PLMA; Laryngeal Mask Company, Henley-on-Thames, United Kingdom) in anesthetized and paralyzed patients.
METHODS: One hundred adult male patients were randomly allocated to an LTSII or PLMArade mark group. The rate of successful insertion, insertion time, airway leak pressure at a cuff pressure of 60 cm H2O, tidal volume during pressure-controlled ventilation, incidence of gas leakage with cuff pressure reduced and with the shaft inclined, position of LTSII under fluoroscopic observation, and postoperative airway morbidity were determined.
RESULTS: Insertion was successful in 37 and 48 of 50 patients with LTSII and PLMA, respectively (P = 0.002), with similar insertion times. Tidal volume was lower with LTSII than with PLMA. Median airway leak pressures of LTSII and PLMA were 16 and 21 cm H2O, respectively (P = 0.006). Gas leakage around the cuff was observed more frequently with LTSII than with PLMA when the cuff pressure was reduced or the shaft of the device inclined. The position of LTSII varied significantly and did not statistically correlate with patient height. Postoperative airway-related morbidity was not significantly different. Finally, tracheal misplacement of LTSII occurred in 5 of 50 patients (10%), but ventilation was possible in 4 of them, and misplacement was identified only after fluoroscopic examination was performed.
CONCLUSION: Airway management with LTSII is inferior to that with PLMA.

Entities:  

Mesh:

Year:  2008        PMID: 18580172     DOI: 10.1097/ALN.0b013e318178819b

Source DB:  PubMed          Journal:  Anesthesiology        ISSN: 0003-3022            Impact factor:   7.892


  11 in total

1.  Prehospital airway management using the laryngeal tube. An emergency department point of view.

Authors:  M Bernhard; W Beres; A Timmermann; R Stepan; C-A Greim; U X Kaisers; A Gries
Journal:  Anaesthesist       Date:  2014-07       Impact factor: 1.041

2.  [Prehospital airway management of laryngeal tubes. Should the laryngeal tube S with gastric drain tube be preferred in emergency medicine?].

Authors:  V Dengler; P Wilde; C Byhahn; M G Mack; R Schalk
Journal:  Anaesthesist       Date:  2010-10-15       Impact factor: 1.041

3.  Airway management in simulated restricted access to a patient--can manikin-based studies provide relevant data?

Authors:  Anders R Nakstad; Mårten Sandberg
Journal:  Scand J Trauma Resusc Emerg Med       Date:  2011-06-13       Impact factor: 2.953

4.  A randomized prospective controlled trial comparing the laryngeal tube suction disposable and the supreme laryngeal mask airway: the influence of head and neck position on oropharyngeal seal pressure.

Authors:  Mostafa Somri; Sonia Vaida; Gustavo Garcia Fornari; Gabriela Renee Mendoza; Pedro Charco-Mora; Naser Hawash; Ibrahim Matter; Forat Swaid; Luis Gaitini
Journal:  BMC Anesthesiol       Date:  2016-10-06       Impact factor: 2.217

Review 5.  Insertion Success of the Laryngeal Tube in Emergency Airway Management.

Authors:  Michael Bernhard; André Gries; Alexandra Ramshorn-Zimmer; Volker Wenzel; Bjoern Hossfeld
Journal:  Biomed Res Int       Date:  2016-08-24       Impact factor: 3.411

6.  A randomised controlled trial comparing ProSeal laryngeal mask airway, i-gel and Laryngeal Tube Suction-D under general anaesthesia for elective surgical patients requiring controlled ventilation.

Authors:  Bikramjit Das; Rahul Varshney; Subhro Mitra
Journal:  Indian J Anaesth       Date:  2017-12

7.  Comparison of laryngeal tube suction II and proseal LMA™ in pediatric patients, undergoing elective surgery.

Authors:  Saurabh Chandrakar; Deepak Kumar Sreevastava; Sidharth Bhasin; Mridul Dhar
Journal:  Saudi J Anaesth       Date:  2017 Oct-Dec

8.  Comparison of five 2nd-generation supraglottic airway devices for airway management performed by novice military operators.

Authors:  Tomas Henlin; Michal Sotak; Petr Kovaricek; Tomas Tyll; Lukas Balcarek; Pavel Michalek
Journal:  Biomed Res Int       Date:  2015-10-01       Impact factor: 3.411

Review 9.  Extraglottic airway devices: technology update.

Authors:  Bimla Sharma; Chand Sahai; Jayashree Sood
Journal:  Med Devices (Auckl)       Date:  2017-08-17

10.  Effectiveness of Proseal laryngeal mask airway and laryngeal tube suction in elective non-laparoscopic surgeries of up to ninety minutes duration: A prospective, randomized study.

Authors:  Swapnil Verma; S P Sharma
Journal:  J Anaesthesiol Clin Pharmacol       Date:  2018 Jan-Mar
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.