Literature DB >> 18579488

Real-time 3D transoesophageal echocardiography for guiding Amplatzer septal occluder device deployment in an adult patient with atrial septal defect.

Philippe Acar1, Pierre Massabuau, Meyer Elbaz.   

Abstract

A 32-year-old male with secundum atrial septal defect underwent percutaneous transcatheter occlusion. The procedure was performed under general anaesthesia and guided by real-time 3D transoesophageal echocardiography (TEE) (i.e. 33, matrix probe 2-7 MHz). The device delivery system was advanced through a femoral vein catheter and placed in the left upper pulmonary vein. A 3D left atrial view was instantaneously obtained. The size of the septal occluder was chosen according to the balloon catheter method. A 12 mm Amplatzer device was deployed under real-time 3D TEE without fluoroscopy. The 3D views depicted the progression of the left-side disc from the left atrial cavity towards the septum. Left and right atrial views demonstrated the perfect application of the device to the atrial septum. Keeping a steady traction on the delivery rod, the right-side disc of the device was then deployed on the right atrial side of the defect. A pushing and pulling of the delivery cable ensured that the device was in a secure and stable position. Absence of peri prosthetic residual shunt was assessed by 2D colour Doppler TEE before release. Transthoracic echocardiography performed the day after ensured the right position of the device. Real-time 3D TEE is a very recent technology allowing on-line guidance of atrial septal occluder device deployment; such imaging should increase delivery safety and decrease fluoroscopy time.

Entities:  

Mesh:

Year:  2008        PMID: 18579488     DOI: 10.1093/ejechocard/jen178

Source DB:  PubMed          Journal:  Eur J Echocardiogr        ISSN: 1532-2114


  5 in total

1.  A case report of percutaneous successful closure of multiple atrial septal defect.

Authors:  Lili Jia; Zhenwen Yang; Xin Du; Zheng Wan; Canliang Huang
Journal:  J Cardiol Cases       Date:  2011-11-09

2.  Assessment of atrial septal defect size and residual rim using real-time 3D transesophageal echocardiography.

Authors:  Kyoko Kaku; Masaaki Takeuchi; Lissa Sugeng; Joseph A Lodato; Hiromi Nakai; Lynn Weinert; Kyoko Otani; Hidetoshi Yoshitani; Nobuhiko Haruki; Ziyad M Hijazi; Yutaka Otsuji; Roberto M Lang
Journal:  J Echocardiogr       Date:  2009-07-14

3.  Retrieval of malpositioned Atrial Septal Occluder (ASO) devices: call for guidelines.

Authors:  Ramesh Varadharajan; Satyen Parida; Ashok Badhe
Journal:  Pediatr Cardiol       Date:  2015-02-03       Impact factor: 1.655

4.  Transcatether closure of an atrial redirection baffle leak.

Authors:  Brian D Soriano; Karen K Stout; Colleen D Cailes; Thomas K Jones
Journal:  Ann Pediatr Cardiol       Date:  2009-01

5.  Percutaneous occluder device closure through femoral vein guidance by transthoracic echocardiography in adult atrial septal defect patients.

Authors:  Yixin Jia; Xu Meng; Yan Li; Chunlei Xu; Wen Zeng; Yuqing Jiao; Wei Han
Journal:  J Thorac Dis       Date:  2018-03       Impact factor: 2.895

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.