The effect of intraluminal content on the bursting strength of vessels ligated with the harmonic ACE and LigaSure V.

Courtney K Phillips1, Gregory W Hruby, Gabriella Mirabile, Piruz Motamedinia, Evren Durak, Daniel S Lehman, Pun Wei Hong, Jaime Landman.   

Abstract

PURPOSE: Energy-based surgical devices (ESDs) are critical for maintaining hemostasis during laparoscopy; however, there are no studies that have evaluated the function of ESDs under different physiologic conditions. We evaluated the effect of intraluminal vessel content on bursting pressure (BP) after ligation with two ESDs: the Harmonic ACE and the LigaSure V.
MATERIALS AND METHODS: Bursting trials were performed on the vasculature of 24 pigs. Blood vessels were distended with blood of different hematocrit concentrations or an albumin solution of varying protein content. The vessel size and BP of each vessel was recorded after ligation with each ESD.
RESULTS: In arteries 0 to 3 mm and veins 0 to 3 mm in size ligated with the Harmonic ACE or the LigaSure V, there were significantly elevated vessel BPs with supraphysiologic intraluminal hematocrits. In arteries and veins ligated with the Harmonic ACE, increasing albumin concentrations also led to increasing BPs, though these maximal BPs were lower than those obtained with supraphysiologic hematocrit levels. Increasing albumin concentrations did not increase the BP of the LigaSure V. Within the ranges tested, there was no decrease in vessel BP associated with anemia.
CONCLUSION: In small vessels, a supraphysiologic hematocrit increased the BP of both arteries and veins when using the Harmonic ACE or the LigaSure V. With the devices tested, anemia did not seem to affect BP. While factors such as intraluminal protein concentration may play a role with ultrasonic energy devices, the mechanism of the increased BP remains unclear. Better understanding of ESDs will help in the design of future devices.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18578667     DOI: 10.1089/end.2008.0079

Source DB:  PubMed          Journal:  J Endourol        ISSN: 0892-7790            Impact factor:   2.942


  3 in total

1.  Surface-processing technology of a microgrooving and water-repellent coating improves the fusion potential of an ultrasonic energy device.

Authors:  Satoru Okada; Junichi Shimada; Kazuhiro Ito; Tatsuo Ishii; Koichiro Oshiumi
Journal:  Surg Endosc       Date:  2016-06-22       Impact factor: 4.584

2.  Safety and efficacy of new integrated bipolar and ultrasonic scissors compared to conventional laparoscopic 5-mm sealing and cutting instruments.

Authors:  Daniel Seehofer; Martina Mogl; Sabine Boas-Knoop; Juliane Unger; Anja Schirmeier; Sascha Chopra; Dennis Eurich
Journal:  Surg Endosc       Date:  2012-03-24       Impact factor: 4.584

3.  Evaluation and Comparison of Contemporary Energy-Based Surgical Vessel Sealing Devices.

Authors:  Zhamshid Okhunov; Renai Yoon; Achim Lusch; Kyle Spradling; Melissa Suarez; Kamaljot S Kaler; Roshan Patel; Christina Hwang; Kathy Osann; Jiaoti Huang; Thomas Lee; Jaime Landman
Journal:  J Endourol       Date:  2018-04       Impact factor: 2.942

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.