Literature DB >> 18577366

Microfluidic immunosensor design for the quantification of interleukin-6 in human serum samples.

Germán A Messina1, Nancy V Panini, Noelia A Martinez, Julio Raba.   

Abstract

Interleukin-6 (IL-6), an inflammatory cytokine, is one of the most important mediators of fever, the acute phase response, and inflammatory conditions. Described here is an integrated microfluidic immunosensor capable of detecting the concentration of IL-6 in human serum samples by use of an electrochemical method in a microfluidic biochip format. The detection of IL-6 was carried out using a sandwich immunoassay method based on the use of anti-IL-6 monoclonal antibodies, immobilized on a 3-aminopropyl-modified controlled-pore glass (APCPG) packet in a central channel (CC) of the microfluidic system. The IL-6 in the serum sample is allowed to react immunologically with the immobilized anti-IL-6 and biotin-labeled second antibodies specific to IL-6. After washing, the streptavidin-alkaline phosphatase conjugate is added. p-Aminophenyl phosphate is converted to p-aminophenol by alkaline phosphatase, and the electroactive product is quantified on a gold electrode at 0.10 V. For electrochemical detection and enzyme immunoassay, the LOD was 0.41 and 1.56 pg mL(-1), respectively. Reproducibility assays employed repetitive standards of IL-6, and the intra- and inter-assay coefficients of variation were below 6.5%. Compared with the traditional IL-6 sensing method, the integrated microfluidic immunosensor required smaller amounts of sample to perform faster detection.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18577366     DOI: 10.1016/j.ab.2008.05.055

Source DB:  PubMed          Journal:  Anal Biochem        ISSN: 0003-2697            Impact factor:   3.365


  6 in total

1.  Multifunctional Dendrimer-templated Antibody Presentation on Biosensor Surfaces for Improved Biomarker Detection.

Authors:  Hye Jung Han; Rangaramanujam M Kannan; Sunxi Wang; Guangzhao Mao; Juan Pedro Kusanovic; Roberto Romero
Journal:  Adv Funct Mater       Date:  2010-02-08       Impact factor: 18.808

2.  Heterogeneous immunoassays in microfluidic format using fluorescence detection with integrated amorphous silicon photodiodes.

Authors:  A T Pereira; P Novo; D M F Prazeres; V Chu; J P Conde
Journal:  Biomicrofluidics       Date:  2011-02-15       Impact factor: 2.800

3.  Modular microfluidic system for on-chip extraction, preconcentration and detection of the cytokine biomarker IL-6 in biofluid.

Authors:  Lucile Alexandre; Amel Bendali; Iago Pereiro; Madad Azimani; Simon Dumas; Laurent Malaquin; Thanh Duc Mai; Stéphanie Descroix
Journal:  Sci Rep       Date:  2022-06-08       Impact factor: 4.996

Review 4.  Physiologically based pharmacokinetic models: integration of in silico approaches with micro cell culture analogues.

Authors:  A Chen; M L Yarmush; T Maguire
Journal:  Curr Drug Metab       Date:  2012-07       Impact factor: 3.731

5.  Development of a Novel Model for the Assessment of Dead-Space Management in Soft Tissue.

Authors:  Rema A Oliver; Vedran Lovric; Yan Yu; Chris Christou; Sean S Aiken; John J Cooper; William R Walsh
Journal:  PLoS One       Date:  2015-08-25       Impact factor: 3.240

Review 6.  Electrochemical Biosensors for Cytokine Profiling: Recent Advancements and Possibilities in the Near Future.

Authors:  Nirmita Dutta; Peter B Lillehoj; Pedro Estrela; Gorachand Dutta
Journal:  Biosensors (Basel)       Date:  2021-03-23
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.