A high-throughput multicomponent screening method for diuretics, masking agents, central nervous system (CNS) stimulants and opiates in human urine by UPLC-MS/MS.

John-Olof Thörngren1, Fredrik Ostervall, Mats Garle.   

Abstract

A simple and rapid multicomponent screening method of 130 substances for direct injections of urine samples has been developed. The fully automated method based on ultra-performance liquid chromatography (UPLC) and tandem mass spectrometry (MS/MS) is used for three different classes of doping agents: diuretics, central nervous system stimulants (CNS stimulants) and opiates. The samples are diluted with buffer containing internal standards (IS) by a pipetting robot system into 96-well plates. Samples are injected on a reversed phase sub 2-microm particle column connected to a fast polarity switching and rapid scanning tandem mass spectrometer with an electrospray interface. The software used to evaluate the results produced reports containing a small-sized window for each component and a data table list with flags to indicate any adverse analytical findings in the sample. The report can also be processed automatically using an application software, which interpret the data and indicate if there is a suspicious sample. One 96-well plate can be analyzed within 16 h. Copyright 2008 John Wiley & Sons, Ltd.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18576434     DOI: 10.1002/jms.1436

Source DB:  PubMed          Journal:  J Mass Spectrom        ISSN: 1076-5174            Impact factor:   1.982


  4 in total

Review 1.  The abuse of diuretics as performance-enhancing drugs and masking agents in sport doping: pharmacology, toxicology and analysis.

Authors:  Amy B Cadwallader; Xavier de la Torre; Alessandra Tieri; Francesco Botrè
Journal:  Br J Pharmacol       Date:  2010-09       Impact factor: 8.739

2.  Renal tubular resistance is the primary driver for loop diuretic resistance in acute heart failure.

Authors:  Jozine M Ter Maaten; Veena S Rao; Jennifer S Hanberg; F Perry Wilson; Lavanya Bellumkonda; Mahlet Assefa; J Sam Broughton; Julie D'Ambrosi; W H Wilson Tang; Kevin Damman; Adriaan A Voors; David H Ellison; Jeffrey M Testani
Journal:  Eur J Heart Fail       Date:  2017-01-19       Impact factor: 15.534

3.  Generic sample preparation combined with high-resolution liquid chromatography-time-of-flight mass spectrometry for unification of urine screening in doping-control laboratories.

Authors:  R J B Peters; J E Oosterink; A A M Stolker; C Georgakopoulos; M W F Nielen
Journal:  Anal Bioanal Chem       Date:  2010-02-16       Impact factor: 4.142

4.  Method development and validation of HPLC tandem/mass spectrometry for quantification of perindopril arginine and amlodipine besylate combination in bulk and pharmaceutical formulations.

Authors:  Kalaiyarasi Duraisamy; K S Jaganathan; Marothu Vamsi Krishna