Literature DB >> 18572188

Optimizing ELISAs for precision and robustness using laboratory automation and statistical design of experiments.

Daniel Joelsson1, Phil Moravec, Matthew Troutman, Joseph Pigeon, Pete DePhillips.   

Abstract

Transferring manual ELISAs to automated platforms requires optimizing the assays for each particular robotic platform. These optimization experiments are often time consuming and difficult to perform using a traditional one-factor-at-a-time strategy. In this manuscript we describe the development of an automated process using statistical design of experiments (DOE) to quickly optimize immunoassays for precision and robustness on the Tecan EVO liquid handler. By using fractional factorials and a split-plot design, five incubation time variables and four reagent concentration variables can be optimized in a short period of time.

Mesh:

Year:  2008        PMID: 18572188     DOI: 10.1016/j.jim.2008.05.012

Source DB:  PubMed          Journal:  J Immunol Methods        ISSN: 0022-1759            Impact factor:   2.303


  6 in total

1.  Ligand binding assays in the 21st Century laboratory: automation.

Authors:  Ago B Ahene; Chris Morrow; David Rusnak; Susan Spitz; Joel Usansky; Holger Pils; Francesca Civoli; Kinnari Pandya; Brian Sue; Daniel Leach; John Derent
Journal:  AAPS J       Date:  2012-03       Impact factor: 4.009

Review 2.  Design and operation of an automated high-throughput monoclonal antibody facility.

Authors:  Daniel Layton; Caroline Laverty; Edouard C Nice
Journal:  Biophys Rev       Date:  2012-10-23

3.  An antigen microarray immunoassay for multiplex screening of mouse monoclonal antibodies.

Authors:  Manlio Di Cristina; Luisa Nunziangeli; Maria Angela Giubilei; Barbara Capuccini; Lorenzo d'Episcopo; Giorgio Mazzoleni; Francesca Baldracchini; Roberta Spaccapelo; Andrea Crisanti
Journal:  Nat Protoc       Date:  2010-11-10       Impact factor: 13.491

Review 4.  Design of Experiments As a Tool for Optimization in Recombinant Protein Biotechnology: From Constructs to Crystals.

Authors:  Christos Papaneophytou
Journal:  Mol Biotechnol       Date:  2019-12       Impact factor: 2.695

5.  Analysis of factors affecting the variability of a quantitative suspension bead array assay measuring IgG to multiple Plasmodium antigens.

Authors:  Itziar Ubillos; Ruth Aguilar; Hector Sanz; Alfons Jiménez; Marta Vidal; Aida Valmaseda; Yan Dong; Deepak Gaur; Chetan E Chitnis; Sheetij Dutta; Evelina Angov; John J Aponte; Joseph J Campo; Clarissa Valim; Jaroslaw Harezlak; Carlota Dobaño
Journal:  PLoS One       Date:  2018-07-02       Impact factor: 3.240

6.  Rational Design of a Glycoconjugate Vaccine against Group A Streptococcus.

Authors:  Roberta Di Benedetto; Francesca Mancini; Martina Carducci; Gianmarco Gasperini; Danilo Gomes Moriel; Allan Saul; Francesca Necchi; Rino Rappuoli; Francesca Micoli
Journal:  Int J Mol Sci       Date:  2020-11-13       Impact factor: 5.923

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.