Literature DB >> 18571964

Surface dose measurements with GafChromic EBT film for 6 and 18MV photon beams.

Hatice Bilge1, Aydin Cakir, Murat Okutan, Hilal Acar.   

Abstract

The aim of this study was to determine the surface doses using GafChromic EBT films and compare them with plane-parallel ionization chamber measurements for 6 and 18 MV high energy photon beams. The measurements were made in a water equivalent solid phantom in the build-up region of the 6 and 18MV photon beams at 100 cm SSD for various field sizes. Markus type plane-parallel ion chamber with fixed-separation between collecting electrodes was used to measure the percent depth doses. GafChromic EBT film measurements were performed both on the phantom surface and maximum dose depth at the same geometry with ion chamber measurements. The surface doses found using GafChromic EBT film were 15%, 20%, 29%and 39%+/-2% (1SD) for 6 MV photons, 6%, 11%, 23% and 32%+/-2% (1SD) for 18 MV photons at 5, 10, 20 and 30 cm(2) field sizes, respectively. GafChromic EBT film provides precise measurements for surface dose in the high energy photons. Agreement between film and plane-parallel chamber measurements was found to be within +/-3% for 18 MV photon beams. There was 5% overestimate on the surface doses when compared with the plane-parallel chamber measurements for all field sizes in the 6 MV photon beams.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18571964     DOI: 10.1016/j.ejmp.2008.05.001

Source DB:  PubMed          Journal:  Phys Med        ISSN: 1120-1797            Impact factor:   2.685


  13 in total

1.  Comparison of Chest Wall and Lymphatic Radiotherapy Techniques in Patients with Left Breast Carcinoma.

Authors:  Melis Gültekin; Mehmet Karabuğa; Ferah Yıldız; Gökhan Özyiğit; Mustafa Cengiz; Faruk Zorlu; Fadıl Akyol; Murat Gürkaynak
Journal:  J Breast Health       Date:  2014-04-01

2.  Skin Surface Dose for Whole Breast Radiotherapy Using Personalized Breast Holder: Comparison with Various Radiotherapy Techniques and Clinical Experiences.

Authors:  Chiu-Ping Chen; Chi-Yeh Lin; Chia-Chun Kuo; Tung-Ho Chen; Shao-Chen Lin; Kuo-Hsiung Tseng; Hao-Wen Cheng; Hsing-Lung Chao; Sang-Hue Yen; Ruo-Yu Lin; Chen-Ju Feng; Long-Sheng Lu; Jeng-Fong Chiou; Shih-Ming Hsu
Journal:  Cancers (Basel)       Date:  2022-06-30       Impact factor: 6.575

3.  The influence of the bolus-surface distance on the dose distribution in the build-up region.

Authors:  Martyna Sroka; Jakub Reguła; Włodzimierz Lobodziec
Journal:  Rep Pract Oncol Radiother       Date:  2010-11-04

4.  Dose distribution comparison in volumetric-modulated arc therapy plans for head and neck cancers with and without an external body contour extended technique.

Authors:  Yoshihiro Tanaka; Hajime Monzen; Kenji Matsumoto; Shinichiro Inomata; Toshiaki Fuse
Journal:  Rep Pract Oncol Radiother       Date:  2019-11-02

5.  Absorption ratio of treatment couch and effect on surface and build-up region doses.

Authors:  Taylan Tuğrul
Journal:  Rep Pract Oncol Radiother       Date:  2017-11-20

6.  On the Use of Optically Stimulated Luminescent Dosimeter for Surface Dose Measurement during Radiotherapy.

Authors:  Fasihah Hanum Yusof; Ngie Min Ung; Jeannie Hsiu Ding Wong; Wei Loong Jong; Vannyat Ath; Vincent Chee Ee Phua; Siew Ping Heng; Kwan Hoong Ng
Journal:  PLoS One       Date:  2015-06-08       Impact factor: 3.240

7.  Comparative evaluation of modern dosimetry techniques near low- and high-density heterogeneities.

Authors:  Eyad A Alhakeem; Sami AlShaikh; Anatoly B Rosenfeld; Sergei F Zavgorodni
Journal:  J Appl Clin Med Phys       Date:  2015-09-08       Impact factor: 2.102

8.  Real-time dosimetry with radiochromic films.

Authors:  Pierluigi Casolaro; Luigi Campajola; Giovanni Breglio; Salvatore Buontempo; Marco Consales; Andrea Cusano; Antonello Cutolo; Francesco Di Capua; Francesco Fienga; Patrizio Vaiano
Journal:  Sci Rep       Date:  2019-03-29       Impact factor: 4.379

9.  Comparison of EBT and EBT3 RadioChromic Film Usage in Parotid Cancer Radiotherapy.

Authors:  M T Bahreyni Toossi; F Khorshidi; M Ghorbani; N Mohamadian; D Davenport
Journal:  J Biomed Phys Eng       Date:  2016-03-01

10.  Characterization of MOSkin detector for in vivo skin dose measurement during megavoltage radiotherapy.

Authors:  Wei Loong Jong; Jeannie Hsiu Ding Wong; Ngie Min Ung; Kwan Hoong Ng; Gwo Fuang Ho; Dean L Cutajar; Anatoly B Rosenfeld
Journal:  J Appl Clin Med Phys       Date:  2014-09-08       Impact factor: 2.102

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.