Various electrochemical approaches, including potentiodynamic polarization, open circuit potential evolution and electrochemical impedance spectroscopy (EIS), are employed to investigate the degradation behavior of biomedical magnesium alloy under the influence of aggressive ions, such as chloride, phosphate, carbonate and sulfate, in a physiological environment. The synergetic effects and mutual influence of these ions on the degradation behavior of Mg are revealed. Our results demonstrate that chloride ions can induce porous pitting corrosion. In the presence of phosphates, the corrosion rate decreases and the formation of pitting corrosion is significantly delayed due to precipitation of magnesium phosphate. Hydrogen carbonate ions are observed to stimulate the corrosion of magnesium alloy during the early immersion stage but they can also induce rapid passivation on the surface. This surface passivation behavior mainly results from the fast precipitation of magnesium carbonate in the corrosion product layer that can subsequently inhibit pitting corrosion completely. Sulfate ions are also found to stimulate magnesium dissolution. These results improve our understanding on the degradation mechanism of surgical magnesium in the physiological environment.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18571486     DOI: 10.1016/j.actbio.2008.05.014

Source DB:  PubMed          Journal:  Acta Biomater        ISSN: 1742-7061            Impact factor:   8.947


  23 in total

1.  Electrochemical characterization and in-vitro bio-assessment of AZ31B and AZ91E alloys as biodegradable implant materials.

Authors:  Zia Ur Rahman; Luis Pompa; Waseem Haider
Journal:  J Mater Sci Mater Med       Date:  2015-07-28       Impact factor: 3.896

2.  Influence of Surrounding Cations on the Surface Degradation of Magnesium Alloy Implants under a Compressive Pressure.

Authors:  Chengyun Ning; Lei Zhou; Ye Zhu; Ying Li; Peng Yu; Shuangying Wang; Tianrui He; Weiping Li; Guoxin Tan; Yingjun Wang; Chuanbin Mao
Journal:  Langmuir       Date:  2015-12-11       Impact factor: 3.882

3.  A novel multilayer model with controllable mechanical properties for magnesium-based bone plates.

Authors:  Juncen Zhou; Wanru Huang; Qing Li; Zuxin She; Funan Chen; Longqin Li
Journal:  J Mater Sci Mater Med       Date:  2015-03-20       Impact factor: 3.896

4.  Poly (3,4-ethylenedioxythiophene) graphene oxide composite coatings for controlling magnesium implant corrosion.

Authors:  Kasey Catt; Huaxiu Li; X Tracy Cui
Journal:  Acta Biomater       Date:  2016-11-17       Impact factor: 8.947

5.  Bioactive Ca-P coating with self-sealing structure on pure magnesium.

Authors:  Junjie Gan; Lili Tan; Ke Yang; Zhuangqi Hu; Qiang Zhang; Xinmin Fan; Yangde Li; Weirong Li
Journal:  J Mater Sci Mater Med       Date:  2013-02-06       Impact factor: 3.896

6.  Nanostructured calcium phosphate coatings on magnesium alloys: characterization and cytocompatibility with mesenchymal stem cells.

Authors:  Maria Emil Iskandar; Arash Aslani; Qiaomu Tian; Huinan Liu
Journal:  J Mater Sci Mater Med       Date:  2015-04-28       Impact factor: 3.896

7.  Electrochemical characteristics of calcium-phosphatized AZ31 magnesium alloy in 0.9 % NaCl solution.

Authors:  Branislav Hadzima; Mansour Mhaede; Filip Pastorek
Journal:  J Mater Sci Mater Med       Date:  2014-01-30       Impact factor: 3.896

8.  In vitro degradation of four magnesium-zinc-strontium alloys and their cytocompatibility with human embryonic stem cells.

Authors:  Aaron F Cipriano; Tong Zhao; Ian Johnson; Ren-Guo Guan; Salvador Garcia; Huinan Liu
Journal:  J Mater Sci Mater Med       Date:  2013-01-30       Impact factor: 3.896

9.  In vivo study of self-assembled alkylsilane coated degradable magnesium devices.

Authors:  Avinash Patil; Samer H Zaky; Rong Chong; Kostas Verdelis; Elia Beniash
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2018-04-11       Impact factor: 3.368

10.  A study on factors affecting the degradation of magnesium and a magnesium-yttrium alloy for biomedical applications.

Authors:  Ian Johnson; Huinan Liu
Journal:  PLoS One       Date:  2013-06-14       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.