Literature DB >> 1857125

Autonomous telemetric capsule to explore the small bowel.

A Lambert1, F Vaxman, F Crenner, T Wittmann, J F Grenier.   

Abstract

An intestinal telemetric capsule has been developed to study the small bowel in man. It consists of a cylinder (11 mm in diameter and 39 mm in length) containing a location detector, a radiotransmitter, a lithium battery and an interchangeable tip. After having been swallowed by the patient, the capsule passes through the whole gut and is recovered in the stools. During the transit through the small bowel, the information provided by the radiotransmitter allows continuous monitoring of the distance covered from the pylorus, the direction and the velocity of progression. Moreover, according to the type of interchangeable tip, it is possible, by remote control, to sample 0.5 ml of intraluminal fluid for subsequent analysis or to release 1 ml of any liquid substance in a precisely determined place for pharmacological studies. The main originality of the capsule is its ability to transmit its precise location inside the small bowel.

Entities:  

Mesh:

Year:  1991        PMID: 1857125     DOI: 10.1007/bf02447107

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  4 in total

1.  ENDORADIOSONDE STUDY OF PROPULSION AND PRESSURE ACTIVITY INDUCED BY TEST MEALS, PROSTIGMINE, AND DIPHENOXYLATE IN THE SMALL INTESTINE.

Authors:  F BARANY; B JACOBSON
Journal:  Gut       Date:  1964-02       Impact factor: 23.059

2.  Wireless telemetering from the digestive tract.

Authors:  A M CONNELL; E N ROWLANDS
Journal:  Gut       Date:  1960-09       Impact factor: 23.059

3.  [Site of fat absorption in the intestinal tract. Studies using a remote control capsule and I-131 labelled fat].

Authors:  A Hemmati
Journal:  Verh Dtsch Ges Inn Med       Date:  1969

4.  A new pressure-sensitive ingestible radio-telemetric capsule.

Authors:  C Browning; R Valori; D L Wingate; D MacLachlan
Journal:  Lancet       Date:  1981-09-05       Impact factor: 79.321

  4 in total
  5 in total

1.  A low-cost biotelemetry system for long time monitoring of physiological data.

Authors:  I Güler; S Kara
Journal:  J Med Syst       Date:  1996-06       Impact factor: 4.460

2.  Automatic tracking system of a miniaturised transmitter for telemetry of physiological parameters.

Authors:  J Jay; R Fouquet; R Rougny
Journal:  Med Biol Eng Comput       Date:  1993-03       Impact factor: 2.602

3.  Small bowel biopsy by remote control: experimental study on dogs.

Authors:  F Vaxman; A Lambert; J F Grenier
Journal:  Dig Dis Sci       Date:  1996-02       Impact factor: 3.199

4.  A compact targeted drug delivery mechanism for a next generation wireless capsule endoscope.

Authors:  Stephen P Woods; Timothy G Constandinou
Journal:  J Microbio Robot       Date:  2016-05-13

5.  Engineering Micromechanical Systems for the Next Generation Wireless Capsule Endoscopy.

Authors:  Stephen Woods; Timothy Constandinou
Journal:  Biomed Res Int       Date:  2015-07-15       Impact factor: 3.411

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.