Literature DB >> 1857124

Optimal control system for the intra-aortic balloon pump.

B Smith1, O Barnea, T W Moore, D Jaron.   

Abstract

An optimal control system for the intra-aortic balloon pump (IABP) is presented. Control of the IABP is based on a performance index formulated to reflect a tradeoff between maximising cardiac oxygen supply and minimising cardiac oxygen consumption. In the performance index, mean diastolic pressure (MDP) was used to represent oxygen availability and peak systolic pressure (PSP) was used to represent oxygen consumption. An algorithm, implemented using an 8-bit microcomputer, changes the deflation time of the IABP to maximise this performance index by using an optimisation technique that employs both a search and an approximation. The search produces three equally spaced points which define a region that includes the maximum of the performance index. From these points, the optimum deflation time is estimated by a quadratic approximation. The algorithm has been successfully tested using performance index curves generated by computer simulations.

Entities:  

Mesh:

Year:  1991        PMID: 1857124     DOI: 10.1007/bf02447105

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  6 in total

1.  On the feasibility of closed-loop control of intra-aortic balloon pumping.

Authors:  J W Clark; G R Kane; H M Bourland
Journal:  IEEE Trans Biomed Eng       Date:  1973-11       Impact factor: 4.538

2.  Automatic control of intra-aortic balloon pumping.

Authors:  G R Kane; J W Clark; H M Bourland; C J Hartley
Journal:  Trans Am Soc Artif Intern Organs       Date:  1971

3.  Control of intraaortic balloon pumping: theory and guidelines for clinical applications.

Authors:  D Jaron; T W Moore; P He
Journal:  Ann Biomed Eng       Date:  1985       Impact factor: 3.934

4.  Optimal QRS detector.

Authors:  N V Thakor; J G Webster; W J Tompkins
Journal:  Med Biol Eng Comput       Date:  1983-05       Impact factor: 2.602

5.  Theoretical considerations regarding the optimization of cardiac assistance by intraaortic balloon pumping.

Authors:  D Jaron; T W Moore; P He
Journal:  IEEE Trans Biomed Eng       Date:  1983-03       Impact factor: 4.538

6.  Experimental determination of optimum performance of counterpulsation assist pumping under computer control.

Authors:  M J Williams; J W Rubin; R G Ellison
Journal:  Comput Biomed Res       Date:  1977-12
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.