Literature DB >> 18571085

Preloaded injector for intraocular lens implantation without the use of ophthalmic viscosurgical devices.

Kimiya Shimizu1, Kenichi Kobayashi, Saiko Takayama, Gu Zhaobin.   

Abstract

PURPOSE: To evaluate a new preloaded intraocular lens (IOL) injector (KS-VF) that uses ordinary irrigating solution alone to implant a foldable IOL and form and maintain the anterior chamber and capsular bag formation and maintenance.
SETTING: Department of Ophthalmology, Kitasato University, School of Medicine, Kanagawa, Japan.
METHODS: The KS-VF disposable injector is preloaded with a 3-piece silicone IOL, which is ejected after the injector is filled with ordinary irrigating solution via an irrigation/aspiration tube connected to the injector body. The space created by the irrigating solution in the anterior chamber and the capsular bag was compared with that created by conventional preloaded injectors filled with an ophthalmic viscosurgical device in a post-phacoemulsification porcine eye. Intraocular lens ejection speed and resistance with the KS-VF injector and with the conventional preloaded injectors were also measured and compared. In addition, intraocular pressure was measured in the porcine eye and in 11 eyes of 11 patients.
RESULTS: In vitro examination revealed no significant difference in the IOL ejection mechanism between the KS-VF and conventional preloaded injectors. The use of irrigating solution was not inferior to that of OVD and provided sufficient space in the anterior chamber and capsular bag. In clinical use, IOLs were successfully implanted without incident into the capsular bag formed with the irrigating solution.
CONCLUSIONS: The KS-VF implants a foldable IOL with irrigating solution alone and requires no intraocular injection or removal of OVD. Possible advantages include improvements in surgical efficiency, avoidance of postoperative IOP rise from residual OVD, and reduced surgical cost.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18571085     DOI: 10.1016/j.jcrs.2008.03.034

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  6 in total

1.  Intraocular lens implantation without the use of ophthalmic viscosurgical device.

Authors:  Ugur Unsal; Gonen Baser; Mehmet Soyler
Journal:  Int Ophthalmol       Date:  2016-03-14       Impact factor: 2.031

2.  Innovative intraocular lens loading magnified.

Authors:  Rengaraj Venkatesh; Bharat Gurnani; Kirandeep Kaur
Journal:  Indian J Ophthalmol       Date:  2020-08       Impact factor: 1.848

3.  Comparison of incision size and intraocular lens performance after implantation with three preloaded systems and one manual delivery system.

Authors:  Javier Mendicute; Thierry Amzallag; Lixin Wang; Aldo A Martinez
Journal:  Clin Ophthalmol       Date:  2018-08-21

4.  Evaluation of semi-preloaded intraocular lens delivery system.

Authors:  Rajesh Rajesh
Journal:  Rom J Ophthalmol       Date:  2019 Jan-Mar

5.  Clinical Evaluation of a Novel Preloaded Intraocular Lens Delivery System During Routine Cataract Surgery.

Authors:  Daniel Black; Dean Corbett; Timothy V Roberts; Brendan Cronin; Pamela J Smith; D Priya Janakiraman; Beth E Jackson
Journal:  Clin Ophthalmol       Date:  2020-08-12

6.  Comparison of a new IOL injector system against 3 standard IOL injector systems with different incision sizes: Miyake-Apple view experimental laboratory study.

Authors:  Lu Zhang; Sonja Schickhardt; Hui Fang; Florian Auerbach; Perfecto Cagampang; Patrick R Merz; Gerd U Auffarth
Journal:  J Cataract Refract Surg       Date:  2022-02-01       Impact factor: 3.351

  6 in total