Literature DB >> 18563853

Calibration laws based on multiple linear regression applied to matrix-assisted laser desorption/ionization Fourier transform ion cyclotron resonance mass spectrometry.

D Keith Williams1, M Ashley Chadwick, Taufika Islam Williams, David C Muddiman.   

Abstract

Operation of any mass spectrometer requires implementation of mass calibration laws to translate experimentally measured physical quantities into a m/z range. While internal calibration in Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR-MS) offers several attractive features, including exposure of calibrant and analyte ions to identical experimental conditions (e.g. space charge), external calibration affords simpler pulse sequences and higher throughput. The automatic gain control method used in hybrid linear trap quadrupole (LTQ) FT-ICR-MS to consistently obtain the same ion population is not readily amenable to matrix-assisted laser desorption/ionization (MALDI) FT-ICR-MS, due to the heterogeneous nature and poor spot-to-spot reproducibility of MALDI. This can be compensated for by taking external calibration laws into account that consider magnetic and electric fields, as well as relative and total ion abundances. Herein, an evaluation of external mass calibration laws applied to MALDI-FT-ICR-MS is performed to achieve higher mass measurement accuracy (MMA). Copyright (c) 2008 John Wiley & Sons, Ltd.

Entities:  

Mesh:

Year:  2008        PMID: 18563853     DOI: 10.1002/jms.1451

Source DB:  PubMed          Journal:  J Mass Spectrom        ISSN: 1076-5174            Impact factor:   1.982


  5 in total

1.  Advanced mass calibration and visualization for FT-ICR mass spectrometry imaging.

Authors:  Donald F Smith; Andriy Kharchenko; Marco Konijnenburg; Ivo Klinkert; Ljiljana Paša-Tolić; Ron M A Heeren
Journal:  J Am Soc Mass Spectrom       Date:  2012-08-28       Impact factor: 3.109

2.  Method for the identification of lipid classes based on referenced Kendrick mass analysis.

Authors:  Larry A Lerno; J Bruce German; Carlito B Lebrilla
Journal:  Anal Chem       Date:  2010-05-15       Impact factor: 6.986

3.  Mass recalibration of FT-ICR mass spectrometry imaging data using the average frequency shift of ambient ions.

Authors:  Jeremy A Barry; Guillaume Robichaud; David C Muddiman
Journal:  J Am Soc Mass Spectrom       Date:  2013-05-29       Impact factor: 3.109

4.  An improved calibration method for the matrix-assisted laser desorption/ionization-Fourier transform ion cyclotron resononance analysis of 15N-metabolically- labeled proteome digests using a mass difference approach.

Authors:  Li Jing; I Jonathan Amster
Journal:  Eur J Mass Spectrom (Chichester)       Date:  2012       Impact factor: 1.067

5.  Bioinformatics Tools for Mass Spectroscopy-Based Metabolomic Data Processing and Analysis.

Authors:  Masahiro Sugimoto; Masato Kawakami; Martin Robert; Tomoyoshi Soga; Masaru Tomita
Journal:  Curr Bioinform       Date:  2012-03       Impact factor: 3.543

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.