Calculation of the replacement correction factors for ion chambers in megavoltage beams by Monte Carlo simulation.

L L W Wang1, D W O Rogers.   

Abstract

This article describes four methods of calculating the replacement correction factor, P(repl0 (or the product p(cav)P(dis) in the IAEA's notation), for a plane-parallel chamber in both electron and photon beams, and for a Farmer chamber in photon beams, by using the EGSnrc Monte Carlo code. The accuracy of underlying assumptions and relative merits of each technique are assessed. With careful selection of parameters it appears that all four methods give reasonable answers although the direct methods are more intellectually satisfying and more accurate in some cases. The direct methods are shown to have an accuracy of 0.11% when appropriate calculation parameters are selected. The depth dependence of P(repl) for the NACP02 plane-parallel chamber has been calculated in both 6 and 18 MeV electron beams. At the reference depth (0.6R50-0.1 cm) P(repl) is 0.9964 for the 6 MeV beam and 1.0005 for the 18 MeV beam for this well-guarded chamber; at the depth of maximum dose for the 18 MeV beam, P(repl) is 1.0010. P(repl) is also calculated for the NACP02 chamber and a Farmer chamber (diameter 6 mm) at a depth of 5 cm in a 60Co photon beam, giving values of 1.0063 and 0.9964, respectively. For the Farmer chamber, P(repl) is about half a percent higher than the value (0.992) recommended by the AAPM dosimetry protocol. It is found that the dosimetry protocols may have adopted an incorrect value of P(repl) for cylindrical chambers in photon beams. The nonunity values of P(repl) for plane-parallel chambers in lower energy electron beams imply a variety of values used in dosimetry protocols must be reassessed.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18561649     DOI: 10.1118/1.2898139

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  5 in total

1.  Monte Carlo calculations of the replacement correction factor, P(repl), for cylindrical chamber cavities in clinical photon and electron beams.

Authors:  Fujio Araki
Journal:  Radiol Phys Technol       Date:  2012-04-22

2.  Perturbation correction factors for cylindrical ionization chambers in high-energy electron beams.

Authors:  Takeshi Ono; Fujio Araki; Fumiaki Yoshiyama
Journal:  Radiol Phys Technol       Date:  2010-02-23

3.  The perturbation correction factors for cylindrical ionization chambers in high-energy photon beams.

Authors:  Fumiaki Yoshiyama; Fujio Araki; Takeshi Ono
Journal:  Radiol Phys Technol       Date:  2010-04-22

4.  Review of fast monte carlo codes for dose calculation in radiation therapy treatment planning.

Authors:  Keyvan Jabbari
Journal:  J Med Signals Sens       Date:  2011-01

5.  Energy-Related Scatter Analysis for Determining the Effective Point of Measurement of Cylindrical Ion Chamber in Heavy Charged Particle Carbon Ion Beam.

Authors:  Xiao-Yun Ma; Yan-Shan Zhang; Wan-Bin Meng; Yin Qi; Qiang Li; Yan-Cheng Ye; Jia-Ming Wu
Journal:  Biomed Res Int       Date:  2021-10-22       Impact factor: 3.411