Literature DB >> 18559751

Modified radical mastectomy with axillary dissection using the electrothermal bipolar vessel sealing system.

Andreas Manouras1, Haridimos Markogiannakis, Michael Genetzakis, George M Filippakis, Emmanuel E Lagoudianakis, Georgia Kafiri, Konstantinos Filis, George C Zografos.   

Abstract

HYPOTHESIS: The use of the electrothermal bipolar vessel sealing system is feasible, safe, and effective in modified radical mastectomy with axillary dissection in terms of lymph vessel sealing, hemostasis, and perioperative complications.
DESIGN: Prospective study.
SETTING: University surgical department. PATIENTS: Between January 1, 2003, and December 31, 2003, 60 patients with locally advanced breast cancer (T2 or T3) admitted for modified radical mastectomy with axillary dissection were included in this study. The entire procedure was performed by the same surgical team using the electrothermal bipolar vessel sealing system. MAIN OUTCOME MEASURES: Final outcome, operative time, hospitalization stay duration, intraoperative blood loss, postoperative mastectomy and axillary drainage volume and duration, and postoperative complications (seroma, bleeding, skin burn, hematoma, lymphedema, pneumothorax, and wound infection or necrosis).
RESULTS: The mean (SD) intraoperative blood loss was 45 (12) mL, and the mean (SD) operative time was 105 (7) minutes. No postoperative bleeding, seroma, hematoma, lymphedema, or other complications occurred. The mean (SD) mastectomy and axillary drainage volumes were 20 (8) and 155 (35) mL, respectively, and the mean (SD) drainage durations were 1.3 (0.2) and 2.7 (0.5) days, respectively. The mean (SD) hospital stay was 3.7 (0.6) days.
CONCLUSIONS: In this first report (to our knowledge) of modified radical mastectomy with axillary dissection using the electrothermal bipolar vessel sealing system, the technique was feasible, safe, and effective. The device simplified the surgical procedure, while achieving efficient lymph vessel sealing and hemostasis. Compared with historical data regarding the conventional or harmonic scalpel, this technique seems to result in reduced operative time, perioperative blood loss, drainage volume and duration, and incidence of seroma or lymphedema. Prospective randomized controlled studies are necessary to evaluate the effect of this technique on perioperative complications.

Entities:  

Mesh:

Year:  2008        PMID: 18559751     DOI: 10.1001/archsurg.143.6.575

Source DB:  PubMed          Journal:  Arch Surg        ISSN: 0004-0010


  12 in total

1.  Micro HTA as a tool for clinical governance: the experience of the Breast Unit in "Santa Maria" Terni Hospital.

Authors:  A Sanguinetti; R Lucchini; R Triola; S Avenia; G Bistoni; C Conti; S Santoprete; N Avenia
Journal:  G Chir       Date:  2013 Nov-Dec

2.  Short- and long-term outcomes of LigaSure versus conventional surgery for curative gastric cancer resection: a matched pair analysis.

Authors:  Haiyang Zhou; Wei Yi; Jian Zhang; Weijun Wang; Yi Wang; Wenchao Gao; Zhiqian Hu
Journal:  Gastric Cancer       Date:  2014-08-17       Impact factor: 7.370

3.  New operative strategy for refractory microcystic lymphangioma.

Authors:  Shigeru Ono; Yuki Tsuji; Katsuhisa Baba; Yoshiko Usui; Satohiko Yanagisawa; Kosaku Maeda
Journal:  Surg Today       Date:  2013-11-30       Impact factor: 2.549

4.  Should a drain be placed in early breast cancer surgery?

Authors:  Florian Ebner; Niko deGregorio; Elena Vorwerk; Wolfgang Janni; Achim Wöckel; Dominic Varga
Journal:  Breast Care (Basel)       Date:  2014-05       Impact factor: 2.860

5.  Axillary lymph node dissection for breast cancer utilizing Harmonic Focus®.

Authors:  Katherine T Ostapoff; David Euhus; Xian-Jin Xie; Madhu Rao; Amy Moldrem; Roshni Rao
Journal:  World J Surg Oncol       Date:  2011-08-15       Impact factor: 2.754

6.  Comparison of skin-sparing mastectomy using LigaSure™ Small Jaw and electrocautery.

Authors:  Young Woo Chang; Hwan Soo Kim; Seung Pil Jung; Sang Uk Woo; Jae Bok Lee; Jeoung Won Bae; Gil Soo Son
Journal:  World J Surg Oncol       Date:  2017-07-14       Impact factor: 2.754

Review 7.  Performance of Harmonic devices in surgical oncology: an umbrella review of the evidence.

Authors:  Hang Cheng; Jeffrey W Clymer; Behnam Sadeghirad; Nicole C Ferko; Chris G Cameron; Joseph F Amaral
Journal:  World J Surg Oncol       Date:  2018-01-04       Impact factor: 2.754

8.  Impact of the surgical modality for axillary lymph node dissection on postoperative drainage and seroma formation after total mastectomy.

Authors:  Hiroshi Isozaki; Yasuhisa Yamamoto; Shigeki Murakami; Sasau Matsumoto; Takehiro Takama
Journal:  Patient Saf Surg       Date:  2019-05-14

9.  Advanced hemostasis in axillary lymph node dissection for locally advanced breast cancer: new technology devices compared in the prevention of seroma formation.

Authors:  Claudio Gambardella; Guglielmo Clarizia; Renato Patrone; Chiara Offi; Claudio Mauriello; Roberto Romano; Marco Filardo; Alessandra Conzo; Alessandro Sanguinetti; Andrea Polistena; Nicola Avenia; Giovanni Conzo
Journal:  BMC Surg       Date:  2019-04-24       Impact factor: 2.102

10.  Seroma formation after breast cancer surgery: what we have learned in the last two decades.

Authors:  Vivek Srivastava; Somprakas Basu; Vijay Kumar Shukla
Journal:  J Breast Cancer       Date:  2012-12-31       Impact factor: 3.588

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.