| Literature DB >> 18558140 |
S A Mir1.
Abstract
A rapid technique for determination of nitrate by acid reduction and diazotization at elevated temperature has been standardized. The technique is based on quantitative diazotization of sulfanilamide by nitrate on incubation in boiling water bath for 3, 5 or 10 min in presence of high concentration of HCl, ca. 64.5%. The diazotized sulfanilamide is coupled at room temperature to N-1-(naphthyl)-ethylenediamine dihydrochloride, and the chromophore evaluated spectrophotometrically at 540 nm. The technique provides linear estimate of nitrate over the test range of 0.5 through 10 microg N mL(-1) sample with all test incubation time periods using alkali nitrate and nitric acid as sources of nitrate anion. Urea treatment enables selective determination of nitrate in presence of nitrite with overall 99+/-1% recovery, and without affecting nitrate determination (P>0.1) or its regression coefficient. The technique has obvious advantages over metal-reduction technique. It is simple, rapid, selective in presence of nitrite, and an inexpensive method for routine determination of nitrate with detection range 0.5-10 microg N mL(-1) sample. Besides, the technique provides opportunity to detect nitric acid as low as 35 microM even in presence of other acids.Entities:
Mesh:
Substances:
Year: 2008 PMID: 18558140 DOI: 10.1016/j.aca.2008.05.038
Source DB: PubMed Journal: Anal Chim Acta ISSN: 0003-2670 Impact factor: 6.558