Literature DB >> 18552948

Single-detector polarization-sensitive optical frequency domain imaging using high-speed intra A-line polarization modulation.

W Y Oh1, B J Vakoc, S H Yun, G J Tearney, B E Bouma.   

Abstract

We demonstrate a novel high-speed polarization-sensitive optical frequency domain imaging system employing high-speed polarization modulation. Rapid and continuous polarization modulation of light prior to illumination of the sample is accomplished by shifting the frequency of one polarization eigenstate by an amount equal to one quarter of the digitization sampling frequency. This approach enables polarization-sensitive imaging with a single detection channel and overcomes artifacts that may arise from temporal variations of the birefringence in fiber-optic imaging probes and spatial variation of birefringence in the sample.

Mesh:

Year:  2008        PMID: 18552948      PMCID: PMC2697108          DOI: 10.1364/ol.33.001330

Source DB:  PubMed          Journal:  Opt Lett        ISSN: 0146-9592            Impact factor:   3.776


  13 in total

1.  Comprehensive volumetric optical microscopy in vivo.

Authors:  Seok H Yun; Guillermo J Tearney; Benjamin J Vakoc; Milen Shishkov; Wang Y Oh; Adrien E Desjardins; Melissa J Suter; Raymond C Chan; John A Evans; Ik-Kyung Jang; Norman S Nishioka; Johannes F de Boer; Brett E Bouma
Journal:  Nat Med       Date:  2006-11-19       Impact factor: 53.440

2.  Jones matrix analysis for a polarization-sensitive optical coherence tomography system using fiber-optic components.

Authors:  B Hyle Park; Mark C Pierce; Barry Cense; Johannes F de Boer
Journal:  Opt Lett       Date:  2004-11-01       Impact factor: 3.776

3.  High-speed fiber based polarization-sensitive optical coherence tomography of in vivo human skin.

Authors:  C E Saxer; J F de Boer; B H Park; Y Zhao; Z Chen; J S Nelson
Journal:  Opt Lett       Date:  2000-09-15       Impact factor: 3.776

4.  Real-time multi-functional optical coherence tomography.

Authors:  Boris Park; Mark Pierce; Barry Cense; Johannes de Boer
Journal:  Opt Express       Date:  2003-04-07       Impact factor: 3.894

5.  High-speed optical frequency-domain imaging.

Authors:  S Yun; G Tearney; Johannes de Boer; N Iftimia; B Bouma
Journal:  Opt Express       Date:  2003-11-03       Impact factor: 3.894

6.  Removing the depth-degeneracy in optical frequency domain imaging with frequency shifting.

Authors:  S Yun; G Tearney; J de Boer; B Bouma
Journal:  Opt Express       Date:  2004-10-04       Impact factor: 3.894

7.  Real-time fiber-based multi-functional spectral-domain optical coherence tomography at 1.3 microm.

Authors:  B Park; Mark C Pierce; Barry Cense; Seok-Hyun Yun; Mircea Mujat; Guillermo Tearney; Brett Bouma; Johannes de Boer
Journal:  Opt Express       Date:  2005-05-30       Impact factor: 3.894

8.  High-speed polarization sensitive optical frequency domain imaging with frequency multiplexing.

Authors:  W Y Oh; S H Yun; B J Vakoc; M Shishkov; A E Desjardins; B H Park; J F de Boer; G J Tearney; B E Bouma
Journal:  Opt Express       Date:  2008-01-21       Impact factor: 3.894

9.  Measurement of collagen and smooth muscle cell content in atherosclerotic plaques using polarization-sensitive optical coherence tomography.

Authors:  Seemantini K Nadkarni; Mark C Pierce; B Hyle Park; Johannes F de Boer; Peter Whittaker; Brett E Bouma; Jason E Bressner; Elkan Halpern; Stuart L Houser; Guillermo J Tearney
Journal:  J Am Coll Cardiol       Date:  2007-03-21       Impact factor: 24.094

10.  Polarization-sensitive optical coherence tomography of invasive basal cell carcinoma.

Authors:  John Strasswimmer; Mark C Pierce; B Hyle Park; Victor Neel; Johannes F de Boer
Journal:  J Biomed Opt       Date:  2004 Mar-Apr       Impact factor: 3.170

View more
  10 in total

1.  Distinguishing Tumor from Associated Fibrosis to Increase Diagnostic Biopsy Yield with Polarization-Sensitive Optical Coherence Tomography.

Authors:  Lida P Hariri; David C Adams; Matthew B Applegate; Alyssa J Miller; Benjamin W Roop; Martin Villiger; Brett E Bouma; Melissa J Suter
Journal:  Clin Cancer Res       Date:  2019-06-07       Impact factor: 12.531

2.  Depth-encoded all-fiber swept source polarization sensitive OCT.

Authors:  Zhao Wang; Hsiang-Chieh Lee; Osman Oguz Ahsen; ByungKun Lee; WooJhon Choi; Benjamin Potsaid; Jonathan Liu; Vijaysekhar Jayaraman; Alex Cable; Martin F Kraus; Kaicheng Liang; Joachim Hornegger; James G Fujimoto
Journal:  Biomed Opt Express       Date:  2014-08-01       Impact factor: 3.732

3.  Fiber-based polarization-sensitive OCT for birefringence imaging of the anterior eye segment.

Authors:  Masahiro Yamanari; Satoru Tsuda; Taiki Kokubun; Yukihiro Shiga; Kazuko Omodaka; Yu Yokoyama; Noriko Himori; Morin Ryu; Shiho Kunimatsu-Sanuki; Hidetoshi Takahashi; Kazuichi Maruyama; Hiroshi Kunikata; Toru Nakazawa
Journal:  Biomed Opt Express       Date:  2015-01-08       Impact factor: 3.732

4.  Seeing beyond the bronchoscope to increase the diagnostic yield of bronchoscopic biopsy.

Authors:  Lida P Hariri; Martin Villiger; Matthew B Applegate; Mari Mino-Kenudson; Eugene J Mark; Brett E Bouma; Melissa J Suter
Journal:  Am J Respir Crit Care Med       Date:  2013-01-15       Impact factor: 21.405

5.  Numerical compensation of system polarization mode dispersion in polarization-sensitive optical coherence tomography.

Authors:  Ellen Ziyi Zhang; Wang-Yuhl Oh; Martin L Villiger; Liang Chen; Brett E Bouma; Benjamin J Vakoc
Journal:  Opt Express       Date:  2013-01-14       Impact factor: 3.894

6.  Tissue-like phantoms for quantitative birefringence imaging.

Authors:  Xinyu Liu; Kathy Beaudette; Xianghong Wang; Linbo Liu; Brett E Bouma; Martin Villiger
Journal:  Biomed Opt Express       Date:  2017-09-12       Impact factor: 3.732

7.  Real-time polarization-sensitive optical coherence tomography data processing with parallel computing.

Authors:  Gangjun Liu; Jun Zhang; Lingfeng Yu; Tuqiang Xie; Zhongping Chen
Journal:  Appl Opt       Date:  2009-11-10       Impact factor: 1.980

Review 8.  Optical measurement of arterial mechanical properties: from atherosclerotic plaque initiation to rupture.

Authors:  Seemantini K Nadkarni
Journal:  J Biomed Opt       Date:  2013-12       Impact factor: 3.170

Review 9.  Fourier-domain optical coherence tomography: recent advances toward clinical utility.

Authors:  Brett E Bouma; Seok-Hyun Yun; Benjamin J Vakoc; Melissa J Suter; Guillermo J Tearney
Journal:  Curr Opin Biotechnol       Date:  2009-03-04       Impact factor: 9.740

10.  Fiber-based polarization-sensitive OCT of the human retina with correction of system polarization distortions.

Authors:  Boy Braaf; Koenraad A Vermeer; Mattijs de Groot; Kari V Vienola; Johannes F de Boer
Journal:  Biomed Opt Express       Date:  2014-07-22       Impact factor: 3.732

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.