Reference dosimetry in a scanned pulsed proton beam using ionisation chambers and a Faraday cup.

Stefan Lorin1, Erik Grusell, Nina Tilly, Joakim Medin, Peter Kimstrand, Bengt Glimelius.   

Abstract

In order to give the correct dose to a patient, the monitor chamber for a proton scanning system has to be calibrated. As recombination of ion pairs occurs in the monitor chamber, the relation between the number of particles traversing it per time unit and the ionization chamber signal is not linear. A method developed for a scanned pulsed proton beam taking the nonlinear monitor signal into account is described. A vital part of the reference dosimetry procedure is to determine the absorbed dose under reference conditions, which is recommended to be done with an ionization chamber. For a scanned pulsed proton beam, the recombination in the ionization chamber is not negligible and the signal from the ionization chamber has to be corrected. In this work, it is shown that although the pulse length is comparable to the ion transit time the beam can be considered as continuously scanned if the applied high voltage is not too small. Also shown is that the two-voltage formula for a continuous beam is under some conditions applicable for a continuous scanned beam as well.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18552418     DOI: 10.1088/0031-9155/53/13/008

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  3 in total

1.  Commissioning dose computation models for spot scanning proton beams in water for a commercially available treatment planning system.

Authors:  X R Zhu; F Poenisch; M Lii; G O Sawakuchi; U Titt; M Bues; X Song; X Zhang; Y Li; G Ciangaru; H Li; M B Taylor; K Suzuki; R Mohan; M T Gillin; N Sahoo
Journal:  Med Phys       Date:  2013-04       Impact factor: 4.071

2.  Use of a novel two-dimensional ionization chamber array for pencil beam scanning proton therapy beam quality assurance.

Authors:  Liyong Lin; Minglei Kang; Timothy D Solberg; Thierry Mertens; Christian Baeumer; Christopher G Ainsley; James E McDonough
Journal:  J Appl Clin Med Phys       Date:  2015-05-08       Impact factor: 2.102

3.  Ultrahigh dose rate pencil beam scanning proton dosimetry using ion chambers and a calorimeter in support of first in-human FLASH clinical trial.

Authors:  Eunsin Lee; Ana Mónica Lourenço; Joseph Speth; Nigel Lee; Anna Subiel; Francesco Romano; Russell Thomas; Richard A Amos; Yongbin Zhang; Zhiyan Xiao; Anthony Mascia
Journal:  Med Phys       Date:  2022-07-14       Impact factor: 4.506

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.