Validation of brachial artery pressure reconstruction from finger arterial pressure.

Ilja Guelen1, Berend E Westerhof, Gertrude L van der Sar, Gert A van Montfrans, Ferdinand Kiemeneij, Karel H Wesseling, Willem Jan W Bos.   

Abstract

OBJECTIVE: Measurement of finger artery pressure with Finapres offers noninvasive continuous blood pressure, which, however, differs from brachial artery pressure. Generalized waveform filtering and level correction may convert the finger artery pressure waveform to a brachial waveform. An upper-arm cuff return-to-flow measurement may be used to calibrate the blood pressure on an individual basis. We tested these corrective methods as implemented in the Finometer device.
METHODS: Intrabrachial artery pressure (BAP) and finger artery pressures were recorded simultaneously in 37 cardiac patients, aged 41-83 years, who underwent a cardiac catheterization procedure. Finger artery pressures were compared after waveform filtering and level correction and after an additional return-to-flow calibration. Measurements were performed in supine and sitting positions. Accuracy and precision were considered clinically acceptable if the mean and standard deviation of the return-to-flow intrabrachial artery pressure (reBAP)-BAP differences were smaller than 5 +/- 8 mmHg (Association for the Advancement of Medical Instrumentation requirements).
RESULTS: Finger artery systolic, diastolic and mean pressures for the group differed from that of intrabrachial artery pressure by -10 +/- 13, -12 +/- 8 and -16 +/- 8 mmHg, respectively. After waveform filtering and level correction the filtered level corrected arterial pressure differed by -1 +/- 11, -0 +/- 7 and -2 +/- 7 mmHg. After individual calibration, reBAP differed by 3 +/- 8, 4 +/- 6 and 3 +/- 5 mmHg. Comparable results were found in the sitting position but only when the supine return-to-flow calibration was used.
CONCLUSION: Reconstruction of intrabrachial artery pressure from finger artery pressure with waveform filtering and level correction reduces the pressure differences substantially, with diastolic and mean within Association for the Advancement of Medical Instrumentation requirements. After one supine return-to-flow calibration, all pressure differences meet the requirements. Return-to-flow calibration should not be repeated in sitting position.

Entities:  

Mesh:

Year:  2008        PMID: 18551006     DOI: 10.1097/HJH.0b013e3282fe1d28

Source DB:  PubMed          Journal:  J Hypertens        ISSN: 0263-6352            Impact factor:   4.844


  33 in total

1.  Noninvasive cardiac output monitoring during exercise testing: Nexfin pulse contour analysis compared to an inert gas rebreathing method and respired gas analysis.

Authors:  Sebastiaan A Bartels; Wim J Stok; Rick Bezemer; Remco J Boksem; Jeroen van Goudoever; Thomas G V Cherpanath; Johannes J van Lieshout; Berend E Westerhof; John M Karemaker; Can Ince
Journal:  J Clin Monit Comput       Date:  2011-10-15       Impact factor: 2.502

2.  Plasma renin and cardiovascular responses to the cold pressor test differ in black and white populations: The SABPA study.

Authors:  L F Gafane; R Schutte; J M Van Rooyen; A E Schutte
Journal:  J Hum Hypertens       Date:  2015-08-27       Impact factor: 3.012

3.  Immediate post-isometric exercise cardiovascular responses are associated with training-induced resting systolic blood pressure reductions.

Authors:  Gavin R Devereux; Jonathan D Wiles; Reuben Howden
Journal:  Eur J Appl Physiol       Date:  2014-10-12       Impact factor: 3.078

4.  Cohort Profile: The Saguenay Youth Study (SYS).

Authors:  Zdenka Pausova; Tomas Paus; Michal Abrahamowicz; Manon Bernard; Daniel Gaudet; Gabriel Leonard; Michel Peron; G Bruce Pike; Louis Richer; Jean R Séguin; Suzanne Veillette
Journal:  Int J Epidemiol       Date:  2017-04-01       Impact factor: 7.196

5.  Respiratory and non-respiratory sinus arrhythmia: implications for heart rate variability.

Authors:  Michael K McMullen; Julie M Whitehouse; Gillian Shine; Anthony Towell
Journal:  J Clin Monit Comput       Date:  2011-12-25       Impact factor: 2.502

6.  Sugar-sweetened soft drink consumption acutely decreases spontaneous baroreflex sensitivity and heart rate variability.

Authors:  Christopher L Chapman; Emma L Reed; Morgan L Worley; Leonard D Pietrafesa; Paul J Kueck; Adam C Bloomfield; Zachary J Schlader; Blair D Johnson
Journal:  Am J Physiol Regul Integr Comp Physiol       Date:  2021-02-03       Impact factor: 3.619

Review 7.  Noninvasive continuous hemodynamic monitoring.

Authors:  Jasper Truijen; Johannes J van Lieshout; Wilbert A Wesselink; Berend E Westerhof
Journal:  J Clin Monit Comput       Date:  2012-06-14       Impact factor: 2.502

8.  Effect of self-initiated and fully-automated self-measurement on blood pressure.

Authors:  Rosanne T Berkhof; Katia Gazzola; Bert-Jan H van den Born
Journal:  J Hum Hypertens       Date:  2019-09-23       Impact factor: 3.012

9.  Acute Beetroot Juice Ingestion Does Not Alter Renal Hemodynamics during Normoxia and Mild Hypercapnia in Healthy Young Adults.

Authors:  Christopher L Chapman; Zachary J Schlader; Emma L Reed; Morgan L Worley; Blair D Johnson
Journal:  Nutrients       Date:  2021-06-09       Impact factor: 5.717

10.  NT-proBNP, C-reactive protein and soluble uPAR in a bi-ethnic male population: the SAfrEIC study.

Authors:  Ruan Kruger; Rudolph Schutte; Hugo W Huisman; Peter Hindersson; Michael H Olsen; Jesper Eugen-Olsen; Aletta E Schutte
Journal:  PLoS One       Date:  2013-03-13       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.