Literature DB >> 18549414

Pitfalls of ultrasound guided vascular access: the use of three/four-dimensional ultrasound.

J L H French1, N J Raine-Fenning, J G Hardman, N M Bedforth.   

Abstract

The use of ultrasound guidance for central venous access is widespread and was recommended as the technique of choice by The National Institute of Clinical Excellence in the UK in 2002. However, complications have been reported using this technique. In this article we review the technique of two-dimensional ultrasound needle guidance and the errors that can occur. We then discuss the development of three- and four-dimensional ultrasound and describe our experiences using this imaging modality in simulated and actual needle-guidance. We discuss the potential advantages for clinicians utilising this newer form of ultrasound imaging for central venous access.

Mesh:

Year:  2008        PMID: 18549414     DOI: 10.1111/j.1365-2044.2008.05513.x

Source DB:  PubMed          Journal:  Anaesthesia        ISSN: 0003-2409            Impact factor:   6.955


  17 in total

1.  Evaluation of vascular puncture needles with specific modifications for enhanced ultrasound visibility: In vitro study.

Authors:  Nobuyuki Kawai; Hiroki Minamiguchi; Morio Sato; Motoki Nakai; Hiroki Sanda; Takami Tanaka; Akira Ikoma; Kouhei Nakata; Shintaro Shirai; Tetsuo Sonomura
Journal:  World J Radiol       Date:  2012-06-28

Review 2.  International evidence-based recommendations on ultrasound-guided vascular access.

Authors:  Massimo Lamperti; Andrew R Bodenham; Mauro Pittiruti; Michael Blaivas; John G Augoustides; Mahmoud Elbarbary; Thierry Pirotte; Dimitrios Karakitsos; Jack Ledonne; Stephanie Doniger; Giancarlo Scoppettuolo; David Feller-Kopman; Wolfram Schummer; Roberto Biffi; Eric Desruennes; Lawrence A Melniker; Susan T Verghese
Journal:  Intensive Care Med       Date:  2012-05-22       Impact factor: 17.440

Review 3.  Focus on peripherally inserted central catheters in critically ill patients.

Authors:  Paolo Cotogni; Mauro Pittiruti
Journal:  World J Crit Care Med       Date:  2014-11-04

4.  Acoustic Radiation Force Impulse (ARFI) imaging-based needle visualization.

Authors:  Veronica Rotemberg; Mark Palmeri; Stephen Rosenzweig; Stuart Grant; David Macleod; Kathryn Nightingale
Journal:  Ultrason Imaging       Date:  2011-01       Impact factor: 1.578

5.  3D biplane versus conventional 2D ultrasound imaging for internal jugular vein cannulation.

Authors:  Harm J Scholten; Michael I Meesters; Leon J Montenij; Erik H M Korsten; R Arthur Bouwman
Journal:  Intensive Care Med       Date:  2021-11-22       Impact factor: 17.440

Review 6.  Ultrasonography as a guide during vascular access procedures and in the diagnosis of complications.

Authors:  A Vezzani; T Manca; A Vercelli; A Braghieri; A Magnacavallo
Journal:  J Ultrasound       Date:  2013-10-29

7.  Recent advance in patient monitoring.

Authors:  Tomoki Nishiyama
Journal:  Korean J Anesthesiol       Date:  2010-09-20

8.  Ultrasound-guided central venous access.

Authors:  Paul Barash
Journal:  F1000 Med Rep       Date:  2009-08-26

Review 9.  Ultrasound guidance versus anatomical landmarks for subclavian or femoral vein catheterization.

Authors:  Patrick Brass; Martin Hellmich; Laurentius Kolodziej; Guido Schick; Andrew F Smith
Journal:  Cochrane Database Syst Rev       Date:  2015-01-09

Review 10.  Ultrasound guidance versus anatomical landmarks for internal jugular vein catheterization.

Authors:  Patrick Brass; Martin Hellmich; Laurentius Kolodziej; Guido Schick; Andrew F Smith
Journal:  Cochrane Database Syst Rev       Date:  2015-01-09
View more