Crestal bone changes at nonsubmerged implants (Camlog) with different machined collar lengths: a histomorphometric pilot study in dogs.

Frank Schwarz1, Monika Herten, Katrin Bieling, Jürgen Becker.   

Abstract

PURPOSE: The aim of the present study was to histomorphometrically investigate crestal bone changes at nonsubmerged implants (Camlog) with different machined collar lengths in a dog model.
MATERIALS AND METHODS: One-stage insertion of sandblasted acid-etched screw-type implants with machined neck sizes of 1.6 mm (CAM) and 0.4 mm (CAM+) was performed in the mandibles of 4 beagle dogs. Both types of implants were inserted so that the implant shoulder (IC) exceeded the alveolar crest for 0.4 mm. Placement was followed by the connection of standard abutments. The animals were sacrificed after 2 and 12 weeks. Dissected blocks were processed for histomorphometric analysis (eg, distance between IC and the coronal extension of bone-implant contact [CBI], the distance between IC and the apical extension of the inflammatory cell infiltrate, and the percentage of bone-implant contact).
RESULTS: Histomorphometric analysis revealed significantly increased mean IC-CBI (CAM: 2.4 +/- 0.3 mm; CAM+: 1.6 +/- 0.1 mm) and BIC (CAM: 77%; CAM+: 80%) values in both groups at 12 weeks. However, mean IC-CBI values were significantly higher in the CAM group (P < .01). An inflammatory cell infiltrate was localized to the implant-abutment interface of both CAM and CAM+ implants, and BC was clearly separated from alCT by a subepithelial connective tissue zone.
CONCLUSIONS: Within the limits of the present study, it was concluded that (1) rough-surfaced implant necks reduced crestal bone level changes after 12 weeks of healing, and (2) microbial leakage apparently did not contribute to the marginal bone resorption in either group.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18548932

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  3 in total

1.  Impact of machined versus structured implant shoulder designs on crestal bone level changes: a randomized, controlled, multicenter study.

Authors:  Daniel Rothamel; Maria Heinz; Daniel Ferrari; Alfons Eissing; Henrik Holtmann; Lara Schorn; Tim Fienitz
Journal:  Int J Implant Dent       Date:  2022-07-16

2.  Sinus Floor Elevation via an Osteotome Technique without Biomaterials.

Authors:  Rodrigo Andrés-García; José Vicente Ríos-Santos; Mariano Herrero-Climent; Pedro Bullón; Javier Fernández-Farhall; Alberto Gómez-Menchero; Ana Fernández-Palacín; Blanca Ríos-Carrasco
Journal:  Int J Environ Res Public Health       Date:  2021-01-27       Impact factor: 3.390

Review 3.  Impact of implant-abutment connection and positioning of the machined collar/microgap on crestal bone level changes: a systematic review.

Authors:  Frank Schwarz; Andrea Hegewald; Jürgen Becker
Journal:  Clin Oral Implants Res       Date:  2013-06-18       Impact factor: 5.977

  3 in total