PURPOSE: To investigate the MacDQoL test-retest reliability and sensitivity to change in vision over a period of one year in a sample of patients with age-related macular degeneration (AMD). DESIGN: A prospective, observational study. METHOD: Patients with AMD from an ophthalmologist's list (n = 135) completed the MacDQoL questionnaire by telephone interview and underwent a vision assessment on two occasions, one year apart. RESULTS: Among participants whose vision was stable over one year (n = 87), MacDQoL scores at baseline and follow-up were highly correlated (r = 0.95; P < .0001). Twelve of the 22 scale items had intraclass correlations of >.80; only two were correlated <.7. There was no difference between baseline and follow-up scores (P = .85), indicating excellent test-retest reliability. Poorer quality of life (QoL) at follow-up, measured by the MacDQoL present QoL overview item, was associated with deterioration in both the better eye and binocular distance visual acuity [VA] (r = 0.29; P = .001, r = 0.21; P = .016, respectively; n = 135). There was a positive correlation between deterioration in the MacDQoL average weighted impact score and deterioration in both binocular near VA and reading speed (r = 0.20; P = .019, r = 0.18; P = .041, respectively; n = 135). CONCLUSION: The MacDQoL has excellent test-retest reliability. Its sensitivity to change in vision status was demonstrated in correlational analyses. The measure indicates that the negative impact of AMD on QoL increases with increasing severity of visual impairment.
PURPOSE: To investigate the MacDQoL test-retest reliability and sensitivity to change in vision over a period of one year in a sample of patients with age-related macular degeneration (AMD). DESIGN: A prospective, observational study. METHOD:Patients with AMD from an ophthalmologist's list (n = 135) completed the MacDQoL questionnaire by telephone interview and underwent a vision assessment on two occasions, one year apart. RESULTS: Among participants whose vision was stable over one year (n = 87), MacDQoL scores at baseline and follow-up were highly correlated (r = 0.95; P < .0001). Twelve of the 22 scale items had intraclass correlations of >.80; only two were correlated <.7. There was no difference between baseline and follow-up scores (P = .85), indicating excellent test-retest reliability. Poorer quality of life (QoL) at follow-up, measured by the MacDQoL present QoL overview item, was associated with deterioration in both the better eye and binocular distance visual acuity [VA] (r = 0.29; P = .001, r = 0.21; P = .016, respectively; n = 135). There was a positive correlation between deterioration in the MacDQoL average weighted impact score and deterioration in both binocular near VA and reading speed (r = 0.20; P = .019, r = 0.18; P = .041, respectively; n = 135). CONCLUSION: The MacDQoL has excellent test-retest reliability. Its sensitivity to change in vision status was demonstrated in correlational analyses. The measure indicates that the negative impact of AMD on QoL increases with increasing severity of visual impairment.
Authors: James Stuart Wolffsohn; Jonathan Jackson; Olivia Anne Hunt; Charles Cottriall; Jennifer Lindsay; Richard Gilmour; Anne Sinclair; Robert Harper Journal: Int J Ophthalmol Date: 2014-02-18 Impact factor: 1.779
Authors: Theodoros P Marakis; Chrysanthi Koutsandrea; Klio I Chatzistefanou; Yannis Tountas Journal: Qual Life Res Date: 2016-09-10 Impact factor: 4.147
Authors: Winfried M Amoaku; Richard P Gale; Andrew J Lotery; Geeta Menon; Sobha Sivaprasad; Jennifer Petrillo; Jennifer Quinn Journal: PLoS One Date: 2015-06-03 Impact factor: 3.240
Authors: Samera Dean; Jonathan M Mathers; Melanie Calvert; Derek G Kyte; Dolores Conroy; Annie Folkard; Sue Southworth; Philip I Murray; Alastair K Denniston Journal: Br J Ophthalmol Date: 2017-04-28 Impact factor: 4.638