Literature DB >> 18546162

Micro-high-performance liquid chromatography platform for the depletion of high-abundance proteins and subsequent on-line concentration/capturing of medium and low-abundance proteins from serum. Application to profiling of protein expression in healthy and osteoarthritis sera by 2-D gel electrophoresis.

Yazen Jmeian1, Ziad El Rassi.   

Abstract

In this investigation, an integrated microcolumn-based fluidic platform for the simultaneous depletion of high-abundance proteins and the subsequent on-line concentration/capturing of medium- and low-abundance proteins from human serum has been introduced. The platform consists of on-line coupling of tandem affinity micorcolumns to an RP microcolumn to achieve first the depletion of high-abundance proteins by the tandem affinity microcolumns followed by the concentration and capturing of medium- and low-abundance proteins by the RP microcolumn. The tandem affinity microcolumns are based on macroporous monoliths characterized by their relatively high permeability in pressure-driven flow while the RP microcolumn is packed with polymeric particles with an average particle diameter of 20 microm giving rise to a very little back pressure, thus allowing fast flow velocity across the coupled columns format and consequently short processing time of serum samples prior to analysis by 2-DE. The microcolumn-based fluidic platform was applied to serum samples from osteoarthritis (OA) donors before and after soy protein (SP) supplementation, and from healthy donors, and the resulting depleted serum samples from high-abundance proteins were profiled for protein expression by 2-DE. In general, the protein expression was lower in serum of the same OA patient after soy treatment than before soy treatment. Several proteins were down-regulated after soy treatment with transthyretin being the most affected by the SP supplementation. In addition, with respect to serum from healthy donors, the sera from OA patients showed difference in proteins expression.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18546162     DOI: 10.1002/elps.200800039

Source DB:  PubMed          Journal:  Electrophoresis        ISSN: 0173-0835            Impact factor:   3.535


  5 in total

Review 1.  Organic monoliths for hydrophilic interaction electrochromatography/chromatography and immunoaffinity chromatography.

Authors:  Dilani N Gunasena; Ziad El Rassi
Journal:  Electrophoresis       Date:  2011-12-07       Impact factor: 3.535

2.  Proteomic analysis of synovial fluid as an analytical tool to detect candidate biomarkers for knee osteoarthritis.

Authors:  Weixiong Liao; Zhongli Li; Hao Zhang; Ji Li; Ketao Wang; Yimeng Yang
Journal:  Int J Clin Exp Pathol       Date:  2015-09-01

3.  Network medicine analysis of chondrocyte proteins towards new treatments of osteoarthritis.

Authors:  Jose C Nacher; Benjamin Keith; Jean-Marc Schwartz
Journal:  Proc Biol Sci       Date:  2014-01-15       Impact factor: 5.349

Review 4.  Analysing the role of endogenous matrix molecules in the development of osteoarthritis.

Authors:  Nidhi Sofat
Journal:  Int J Exp Pathol       Date:  2009-10       Impact factor: 1.925

5.  Automated sample preparation platform for mass spectrometry-based plasma proteomics and biomarker discovery.

Authors:  Vilém Guryča; Daniel Roeder; Paolo Piraino; Jens Lamerz; Axel Ducret; Hanno Langen; Paul Cutler
Journal:  Biology (Basel)       Date:  2014-03-11
  5 in total