Literature DB >> 18545052

Failure causes, timing, and cluster behavior: an 8-year study of dental implants.

Devorah Schwartz-Arad1, Amir Laviv, Liran Levin.   

Abstract

OBJECTIVES: The aim of this study was to analyze implant failure, causes, time of failure, and cluster behavior of implant failure among patients referred to a private surgical center.
METHODS: All failed implants placed during the years 1997-2004 were analyzed. Data collected included age, gender, smoking habits, implant type and dimensions, timing of implantation (immediate or nonimmediate), time to failure, and failure causes.
RESULTS: Overall, 99 of the 3609 implants placed between the years 1997 and 2004 failed in 61 patients resulting in a 97.3% survival rate. Patients with implant failure ranged in age from 21 to 78 years (average 54 years); 34% were men, 66% women; smoking was reported by 32.8%, pastsmoking 16.4%; time from implant placement to failure ranged from 1 to 99 months (average 24 months, SD = 24.8). Common causes for implant removal were bone loss and/or inflammation (52.5%), and implant mobility (43.4%). Cluster behavior (ie, more than one implant failure per patient, not necessarily in the same area or quadrant) was shown in one-third (32.8%) of the patients in which 56.6% of all failures were found. This cluster pattern was evident in both the surgical and prosthetic phase failures.
CONCLUSION: There is a higher probability for a cluster pattern among patients with implant failure. Common signs for failure are implant mobility (surgical phase) and infection and marginal bone loss (prosthetic phase).

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18545052     DOI: 10.1097/ID.0b013e3181777906

Source DB:  PubMed          Journal:  Implant Dent        ISSN: 1056-6163            Impact factor:   2.454


  13 in total

1.  Enamel matrix derivative enhances the proliferation and osteogenic differentiation of human periodontal ligament stem cells on the titanium implant surface.

Authors:  Guang Li; Jing Hu; Hui Chen; Liang Chen; Na Zhang; Lisheng Zhao; Ning Wen; Yongjin Yang
Journal:  Organogenesis       Date:  2017-06-09       Impact factor: 2.500

2.  Development of a new preclinical model to study early implant loss: a validation study in the beagle dog.

Authors:  Antonio Liñares; Raul Verdeja; Benjamin Pippenger; Fernando Muñoz; Mónica López-Peña; Juan Blanco
Journal:  Clin Oral Investig       Date:  2022-07-26       Impact factor: 3.606

Review 3.  Diagnostic tests for titanium hypersensitivity in implant dentistry: a systematic review of the literature.

Authors:  Lena Katharina Müller-Heupt; Eik Schiegnitz; Sebahat Kaya; Elisabeth Jacobi-Gresser; Peer Wolfgang Kämmerer; Bilal Al-Nawas
Journal:  Int J Implant Dent       Date:  2022-07-11

4.  A retrospective study on related factors affecting the survival rate of dental implants.

Authors:  Hee-Won Jang; Jeong-Kyung Kang; Ki Lee; Yong-Sang Lee; Pil-Kyoo Park
Journal:  J Adv Prosthodont       Date:  2011-12-28       Impact factor: 1.904

5.  A two-short-implant-supported molar restoration in atrophic posterior maxilla: A finite element analysis.

Authors:  Ho-Yong Song; Yoon-Hyuk Huh; Chan-Jin Park; Lee-Ra Cho
Journal:  J Adv Prosthodont       Date:  2016-08-18       Impact factor: 1.904

Review 6.  The relationship between single nucleotide polymorphisms and dental implant loss: a scoping review.

Authors:  Frederick Zhang; Joseph Finkelstein
Journal:  Clin Cosmet Investig Dent       Date:  2019-05-31

7.  Fabrication and in vitro release behavior of a novel antibacterial coating containing halogenated furanone-loaded poly(L-lactic acid) nanoparticles on microarc-oxidized titanium.

Authors:  Yicheng Cheng; Jiang Wu; Bo Gao; Xianghui Zhao; Junyan Yao; Shenglin Mei; Liang Zhang; Huifang Ren
Journal:  Int J Nanomedicine       Date:  2012-11-07

8.  Comparisons of maximum deformation and failure forces at the implant-abutment interface of titanium implants between titanium-alloy and zirconia abutments with two levels of marginal bone loss.

Authors:  Chiung-Fang Wang; Heng-Li Huang; Dan-Jae Lin; Yen-Wen Shen; Lih-Jyh Fuh; Jui-Ting Hsu
Journal:  Biomed Eng Online       Date:  2013-05-20       Impact factor: 2.819

9.  Effect of enamel matrix derivative on bone formation around intraosseous titanium implant: An experimental study in canine model.

Authors:  Reza Birang; Mohammad Shahabooei; Fatemeh Mashhadiabbas; Mehdi Atabaki; Narges Naghsh; Keikavous Kavosh; Ehsan Birang; Ahmad Mogharehabed
Journal:  Dent Res J (Isfahan)       Date:  2012-11

10.  In vivo evaluation of an antibacterial coating containing halogenated furanone compound-loaded poly(l-lactic acid) nanoparticles on microarc-oxidized titanium implants.

Authors:  Yicheng Cheng; Bo Gao; Xianghui Liu; Xianghui Zhao; Weige Sun; Huifang Ren; Jiang Wu
Journal:  Int J Nanomedicine       Date:  2016-03-30
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.