A measurement system and image reconstruction in magnetic induction tomography.

M Vauhkonen1, M Hamsch, C H Igney.   

Abstract

Magnetic induction tomography (MIT) is a technique for imaging the internal conductivity distribution of an object. In MIT current-carrying coils are used to induce eddy currents in the object and the induced voltages are sensed with other coils. From these measurements, the internal conductivity distribution of the object can be reconstructed. In this paper, we introduce a 16-channel MIT measurement system that is capable of parallel readout of 16 receiver channels. The parallel measurements are carried out using high-quality audio sampling devices. Furthermore, approaches for reconstructing MIT images developed for the 16-channel MIT system are introduced. We consider low conductivity applications, conductivity less than 5 S m(-1), and we use a frequency of 10 MHz. In the image reconstruction, we use time-harmonic Maxwell's equation for the electric field. This equation is solved with the finite element method using edge elements and the images are reconstructed using a generalized Tikhonov regularization approach. Both difference and static image reconstruction approaches are considered. Results from simulations and real measurements collected with the Philips 16-channel MIT system are shown.

Mesh:

Substances:

Year:  2008        PMID: 18544825     DOI: 10.1088/0967-3334/29/6/S37

Source DB:  PubMed          Journal:  Physiol Meas        ISSN: 0967-3334            Impact factor:   2.833


  4 in total

1.  Numerical modeling of magnetic induction tomography using the impedance method.

Authors:  Airton Ramos; Julia G B Wolff
Journal:  Med Biol Eng Comput       Date:  2011-01-13       Impact factor: 2.602

2.  Forward modelling of magnetic induction tomography: a sensitivity study for detecting haemorrhagic cerebral stroke.

Authors:  M Zolgharni; P D Ledger; H Griffiths
Journal:  Med Biol Eng Comput       Date:  2009-10-16       Impact factor: 2.602

3.  A feasibility study of altered spatial distribution of losses induced by eddy currents in body composition analysis.

Authors:  Kim H Blomqvist; Raimo E Sepponen
Journal:  Biomed Eng Online       Date:  2010-11-04       Impact factor: 2.819

Review 4.  Screening and Biosensor-Based Approaches for Lung Cancer Detection.

Authors:  Lulu Wang
Journal:  Sensors (Basel)       Date:  2017-10-23       Impact factor: 3.576

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.