Literature DB >> 18542701

Polarization-sensitive swept-source optical coherence tomography with continuous source polarization modulation.

Masahiro Yamanari1, Shuichi Makita, Yoshiaki Yasuno.   

Abstract

We present fiber-based polarization-sensitive swept-source optical coherence tomography (SS-OCT) based on continuous source polarization modulation. The light source is a frequency swept laser centered at 1.31 microm with a scanning rate of 20 kHz. The incident polarization is modulated by a resonant electro-optic modulator at 33.3 MHz, which is one-third of the data acquisition frequency. The zeroth- and first-order harmonic components of the OCT signals with respect to the polarization modulation frequency have the polarimetric information of the sample. By algebraic and matrix calculations of the signals, this system can measure the depth-resolved Jones matrices of the sample with a single wavelength scan. The phase fluctuations of the starting trigger of wavelength scan and the polarization modulation are cancelled by monitoring the OCT phase of a calibration mirror inserted into the sample arm. We demonstrate the potential of the system by the measurement of chicken breast muscle and the volumetric measurement of an in vivo human anterior eye segment. The phase retardation image shows an additional contrast in the fibrous tissue such as the collagen fiber in the trabecular meshwork and sclera.

Entities:  

Mesh:

Year:  2008        PMID: 18542701     DOI: 10.1364/oe.16.005892

Source DB:  PubMed          Journal:  Opt Express        ISSN: 1094-4087            Impact factor:   3.894


  39 in total

1.  Birefringence imaging of posterior eye by multi-functional Jones matrix optical coherence tomography.

Authors:  Satoshi Sugiyama; Young-Joo Hong; Deepa Kasaragod; Shuichi Makita; Sato Uematsu; Yasushi Ikuno; Masahiro Miura; Yoshiaki Yasuno
Journal:  Biomed Opt Express       Date:  2015-11-19       Impact factor: 3.732

2.  Depth-encoded all-fiber swept source polarization sensitive OCT.

Authors:  Zhao Wang; Hsiang-Chieh Lee; Osman Oguz Ahsen; ByungKun Lee; WooJhon Choi; Benjamin Potsaid; Jonathan Liu; Vijaysekhar Jayaraman; Alex Cable; Martin F Kraus; Kaicheng Liang; Joachim Hornegger; James G Fujimoto
Journal:  Biomed Opt Express       Date:  2014-08-01       Impact factor: 3.732

3.  Optically buffered Jones-matrix-based multifunctional optical coherence tomography with polarization mode dispersion correction.

Authors:  Young-Joo Hong; Shuichi Makita; Satoshi Sugiyama; Yoshiaki Yasuno
Journal:  Biomed Opt Express       Date:  2014-12-18       Impact factor: 3.732

4.  Quantitative single-mode fiber based PS-OCT with single input polarization state using Mueller matrix.

Authors:  Zhenyang Ding; Chia-Pin Liang; Qinggong Tang; Yu Chen
Journal:  Biomed Opt Express       Date:  2015-04-22       Impact factor: 3.732

5.  Retinal nerve fiber bundle tracing and analysis in human eye by polarization sensitive OCT.

Authors:  Mitsuro Sugita; Michael Pircher; Stefan Zotter; Bernhard Baumann; Philipp Roberts; Tomoyuki Makihira; Nobuhiro Tomatsu; Makoto Sato; Clemens Vass; Christoph K Hitzenberger
Journal:  Biomed Opt Express       Date:  2015-02-26       Impact factor: 3.732

6.  Fiber-based polarization-sensitive OCT for birefringence imaging of the anterior eye segment.

Authors:  Masahiro Yamanari; Satoru Tsuda; Taiki Kokubun; Yukihiro Shiga; Kazuko Omodaka; Yu Yokoyama; Noriko Himori; Morin Ryu; Shiho Kunimatsu-Sanuki; Hidetoshi Takahashi; Kazuichi Maruyama; Hiroshi Kunikata; Toru Nakazawa
Journal:  Biomed Opt Express       Date:  2015-01-08       Impact factor: 3.732

7.  Noise-bias and polarization-artifact corrected optical coherence tomography by maximum a-posteriori intensity estimation.

Authors:  Aaron C Chan; Young-Joo Hong; Shuichi Makita; Masahiro Miura; Yoshiaki Yasuno
Journal:  Biomed Opt Express       Date:  2017-03-03       Impact factor: 3.732

8.  Visualization of prostatic nerves by polarization-sensitive optical coherence tomography.

Authors:  Yeoreum Yoon; Seung Hwan Jeon; Yong Hyun Park; Won Hyuk Jang; Ji Youl Lee; Ki Hean Kim
Journal:  Biomed Opt Express       Date:  2016-08-01       Impact factor: 3.732

9.  Real-time polarization-sensitive optical coherence tomography data processing with parallel computing.

Authors:  Gangjun Liu; Jun Zhang; Lingfeng Yu; Tuqiang Xie; Zhongping Chen
Journal:  Appl Opt       Date:  2009-11-10       Impact factor: 1.980

10.  Polarization maintaining fiber based ultra-high resolution spectral domain polarization sensitive optical coherence tomography.

Authors:  Erich Götzinger; Bernhard Baumann; Michael Pircher; Christoph K Hitzenberger
Journal:  Opt Express       Date:  2009-12-07       Impact factor: 3.894

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.