Quantitative micro-computed tomography: a non-invasive method to assess equivalent bone mineral density.

Ara Nazarian1, Brian D Snyder, David Zurakowski, Ralph Müller.   

Abstract

One of the many applications of micro computed tomography (microCT) is to accurately visualize and quantify cancellous bone microstructure. However, microCT based assessment of bone mineral density has yet to be thoroughly investigated. Specifically, the effects of varying imaging parameters, such as tube voltage (kVp), current (microA), integration time (ms), object to X-ray source distance (mm), projection number, detector array size and imaging media (surrounding the specimen), on the relationship between equivalent tissue density (rhoEQ) and its linear attenuation coefficient (micro) have received little attention. In this study, in house manufactured, hydrogen dipotassium phosphate liquid calibration phantoms (K2HPO4) were employed in addition to a resin embedded hydroxyapatite solid calibration phantoms supplied by Scanco Medical AG Company. Variations in current, integration time and projection number had no effect on the conversion relationship between micro and rhoEQ for the K2HPO4 and Scanco calibration phantoms [p>0.05 for all cases]. However, as expected, variations in scanning tube voltage, object to X-ray source distance, detector array size and imaging media (referring to the solution that surrounds the specimen in the imaging vial) significantly affected the conversion relationship between mu and rhoEQ for K2HPO4 and Scanco calibration phantoms [p<0.05 for all cases]. A multivariate linear regression approach was used to estimate rhoEQ based on attenuation coefficient, tube voltage, object to X-ray source distance, detector array size and imaging media for K2HPO4 liquid calibration phantoms, explaining 90% of the variation in rhoEQ. Furthermore, equivalent density values of bovine cortical bone (converted from attenuation coefficient to equivalent density using the K2HPO4 liquid calibration phantoms) samples highly correlated [R2=0.92] with the ash densities of the samples. In conclusion, Scanco calibration phantoms can be used to assess equivalent bone mineral density; however, they cannot be scanned with a specimen or submerged in a different imaging media. The K2HPO4 liquid calibration phantoms provide a cost effective, easy to prepare and convenient means to perform quantitative microCT analysis using any microCT system, with the ability to choose different imaging media according to study needs. However, as with any liquid calibration phantom, they are susceptible to degradation over time.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18539557     DOI: 10.1016/j.bone.2008.04.009

Source DB:  PubMed          Journal:  Bone        ISSN: 1873-2763            Impact factor:   4.398


  43 in total

Review 1.  Application of polychromatic µCT for mineral density determination.

Authors:  W Zou; N Hunter; M V Swain
Journal:  J Dent Res       Date:  2010-09-21       Impact factor: 6.116

2.  Characterization of the trabecular bone structure using frequency modulated ultrasound pulse.

Authors:  Wei Lin; Yi Xia; Yi-Xian Qin
Journal:  J Acoust Soc Am       Date:  2009-06       Impact factor: 1.840

3.  Morphology of the human vertebral endplate.

Authors:  Azucena G Rodriguez; Ana E Rodriguez-Soto; Andrew J Burghardt; Sigurd Berven; Sharmila Majumdar; Jeffrey C Lotz
Journal:  J Orthop Res       Date:  2011-08-02       Impact factor: 3.494

4.  The tethering function of mitofusin2 controls osteoclast differentiation by modulating the Ca2+-NFATc1 axis.

Authors:  Anna Ballard; Rong Zeng; Allahdad Zarei; Christine Shao; Linda Cox; Hui Yan; Antonietta Franco; Gerald W Dorn; Roberta Faccio; Deborah J Veis
Journal:  J Biol Chem       Date:  2020-03-12       Impact factor: 5.157

Review 5.  Hierarchical microimaging of bone structure and function.

Authors:  Ralph Müller
Journal:  Nat Rev Rheumatol       Date:  2009-07       Impact factor: 20.543

6.  Effect of intraspecimen spatial variation in tissue mineral density on the apparent stiffness of trabecular bone.

Authors:  Narges Kaynia; Elaine Soohoo; Tony M Keaveny; Galateia J Kazakia
Journal:  J Biomech Eng       Date:  2015-01       Impact factor: 2.097

7.  Compressive axial mechanical properties of rat bone as functions of bone volume fraction, apparent density and micro-ct based mineral density.

Authors:  Esther Cory; Ara Nazarian; Vahid Entezari; Vartan Vartanians; Ralph Müller; Brian D Snyder
Journal:  J Biomech       Date:  2009-12-08       Impact factor: 2.712

8.  Pulsed low-dose RANKL as a potential therapeutic for postmenopausal osteoporosis.

Authors:  Anna Cline-Smith; Jesse Gibbs; Elena Shashkova; Zachary S Buchwald; Deborah V Novack; Rajeev Aurora
Journal:  JCI Insight       Date:  2016-08-18

9.  Long circulating enzyme replacement therapy rescues bone pathology in mucopolysaccharidosis VII murine model.

Authors:  Daniel J Rowan; Shunji Tomatsu; Jeffrey H Grubb; Bisong Haupt; Adriana M Montaño; Hirotaka Oikawa; Angela C Sosa; Anping Chen; William S Sly
Journal:  Mol Genet Metab       Date:  2012-07-14       Impact factor: 4.797

10.  Specimen size and porosity can introduce error into microCT-based tissue mineral density measurements.

Authors:  Roberto J Fajardo; Esther Cory; Nipun D Patel; Ara Nazarian; Andres Laib; Rajaram K Manoharan; James E Schmitz; Jeremy M DeSilva; Laura M MacLatchy; Brian D Snyder; Mary L Bouxsein
Journal:  Bone       Date:  2008-09-10       Impact factor: 4.398

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.